Study name Efficacy of 940 nm diode laser on the treatment of dentin hypersensitivity in periodontal maintenance patients
Methods RCT, split‐mouth design
Sample size: 45 teeth
Study duration: 30 days
Participants Age: 22 to 57 years
Inclusion criteria: individuals who have passed 1st phase of periodontal treatments and have dentine hypersensitivity in teeth with no caries, fracture; any clear tooth crack, fillings and periapical lesion, which will respond to both air and tactile stimuli application tests
Exclusion criteria: individuals with systemic diseases; allergy to materials used in the study; smokers; individuals with active periodontal diseases; pregnant and lactating women; patients who have received treatments related to increased tooth sensitivity; teeth with occlusal overload and recent occlusal re‐adjustment therapy
Interventions Group 1: control group: placebo
Group 2: potassium fluoride gel 2%
Group 3: laser diode of 940 wavelength
Group 4: laser + potassium fluoride gel 2%
Outcomes Sensitivity to air and tactile stimulation using VAS score
Starting date 11 January 2016
Contact information Tahere Pourseyedian, th.1362@yahoo.com