Skip to main content
. 2021 Mar 29;479(8):1712–1724. doi: 10.1097/CORR.0000000000001737

Table 5.

Correlations of the maximum contact pressure with radiographic and CT parameters in the standing position\

Parameters Hip dysplasia Control
Correlation coefficienta p value Correlation coefficienta p value
Radiographic parameters
 Lateral center-edge angle -0.58 < 0.001 -0.19 0.48
 Tönnis angle 0.50 0.003 0.16 0.55
 Extrusion index 0.53 0.002 0.01 0.99
 Anterior wall index -0.45 0.01 -0.01 0.99
 Posterior wall index -0.11 0.55 0.29 0.28
CT parameters
 Lateral center-edge angle -0.70 < 0.001 -0.21 0.43
 Anterior center-edge angle -0.59 < 0.001 -0.15 0.58
 Posterior center-edge angle -0.16 0.38 0.17 0.52
 Acetabular roof obliquity 0.57 < 0.001 0.16 0.55
 Acetabular inclination angle 0.55 0.001 -0.19 0.47
 Acetabular anteversion angle 0.22 0.23 0.27 0.31
Sagittal pelvic tilt
 Standing APP angle -0.46 0.008 -0.24 0.36
a

Pearson or Spearman correlation coefficients.