Skip to main content
. 2021 Jul 14;109:209–216. doi: 10.1016/j.ijid.2021.07.016

Table 3.

Changes in chest computed tomography scan at 3 months.

Baseline Follow-up Evolution P-value
Delay between baseline evaluation and follow-up visit, median (IQR) - 94 (76–114)
n (%) Ground glass opacities 145 (98.0) 102 (68.9) <0.0001a
n (%) Bronchiectasis 5 (3.4) 10 (6.8) 0.059a
n (%) Reticular pattern 5 (3.4) 7 (4.7) 0.32a
n (%) Honeycombing 3 (2.0) 1 (0.7) 0.16a
n (%) Pleural effusion 15 (10.1) 6 (4.0) 0.020a
n (%) Crazy paving 91 (61.5) 8 (5.4) <0.0001a
n (%) Thin condensations 128 (86.5) 101 (68.2) <0.0001a
n (%) Organizing pneumonia 9 (6.1) 1 (0.7) 0.011a
n (%) Condensation 69 (46.6) 20 (13.5) <0.0001a
Lung involvement (%)
 Mean ± SD 32.4 ± 21.4 10.4 ± 14.9 -22.0 ± 23.1 <0.0001b

IQR, interquartile range; SD, standard deviation.

a

McNemar test.

b

Student's t-test.