Table 5.
CPA results for in vivo HSV case of study. The CPA estimates include the absolute pressure and the relative pressure with respect to the normal loudness case.
Subjective Loudness | Sound Pressure Level dB ref: 20 μPa | Contact Pressure (Estimated) kPa | Ratio with Respect to Normal Loudness |
---|---|---|---|
Soft | 72.9 | 1.03 | 0.58 |
Normal | 81.8 | 1.77 | 1.00 |
Loud | 93.3 | 3.76 | 2.13 |