Skip to main content
. 2021 Jun 14;13(6):e15646. doi: 10.7759/cureus.15646

Table 2. Conventional VMAT TBI and SIMBa planning aims.

VMAT: volumetric modulated arc therapy; SIMBa: simultaneous integrated marrow and body approach; TBI: total body irradiation

Name of Structure Conventional VMAT TBI SIMBa
PTV_Marrow - D90% >= 12 Gy
PTV_TotalBody - D90% >= 8 Gy
PTV_BodyEval Max[Gy] < 16  ; D90% >= 12 Gy  Max [ Gy] < 16
_LungEval Mean [Gy} < 8 Gy Mean [ Gy] < 8 
Spinal Cord Max [Gy] < 15 @ 0.125cc Max [Gy] < 15 @ 0.125cc
Oral Cavity Max [Gy] < 15 @ 0.125cc Max [Gy] < 15 @ 0.125cc
Bowel Max [Gy] < 15 @ 0.125cc Max [Gy] < 15 @ 0.125cc
Kidney (individual) Mean [Gy] < 13  Mean [Gy] < 13 
Whole Brain Max [Gy] < 15 @ 0.125cc Max [Gy] < 15 @ 0.125cc