Skip to main content
. 2021 Jul 13;3(7):e0486. doi: 10.1097/CCE.0000000000000486

TABLE 2.

Bedside Assessment of Safety for VT Titration

Physiologic Variables Mechanism Threshold (cm H2O)
Plateau pressure Maximal pressure across the respiratory system at the end of tidal breath 28
Static total mechanical stress and barotrauma
Transpulmonary plateau pressure Maximal pressure across the lung at the end of tidal breath 22–24
Mechanical stress and barotrauma to the lung
Driving pressure Dynamic pressure change during tidal breath applied to the respiratory system 14
Dynamic mechanical stress and strain
Driving transpulmonary pressure Dynamic pressure change during tidal breath applied to the lung 8–10
Dynamic mechanical stress and strain to the lung
Stress index `Worsening of respiratory system compliance during tidal breath 1
Overdistension and barotrauma