Skip to main content
. 2021 Jun 18;3:100053. doi: 10.1016/j.bioflm.2021.100053

Table 2.

Model fitting parameters and coefficient of determination.

Description Parameter Value Unit
Maximum cathodic current density joc,max 2.402 A m−2
Half-saturation constant KM,c 75.6 μM
Lumped constant potential loss EL 0.428 V
Resistance responsible for ohmic loss RL 2.80 Ω
Coefficient of determination R2 0.971 Unitless