IC50, CC50, and SI values for GSK717 and GSK583 at low MOIs (0.05 to 0.1)a

Virusb GSK717
GSK583
IC50 (μM) CC50 (μM) SI IC50 (μM) CC50 (μM) SI
ZIKV 14.84 82.84 5.58 22.03 104.76 4.76
DENV 20.26 63.59 3.14 18.90 104.76 5.54
MAYV 12.69 63.59 5.01 19.85 104.76 5.28
CVB5 9.57 81.95 8.56 0.11 104.76 952.36
SARS-CoV-2 10.22 75.30 7.37 11.70 61.29 5.24
a

CC50, 50% cytotoxic concentration.

b

Results are from infected A549 (Zika virus [ZIKV], dengue virus 2 [DENV], coxsackievirus B5 [CVB5], or Mayaro virus [MAYV]) and ACE2-SK-N-SH (severe acute respiratory syndrome coronavirus 2 [SARS-CoV-2]) cells. Values for GSK717 were also determined using ZIKV-infected human fetal astrocytes. While GSK583 data were generated at 24 h, GSK717 values were generated at 24 h (CVB5) and 48 h (ZIKV, DENV-2, MAYV, and SARS-CoV-2).