Table 1.
F1 integral score (mean ± standard deviation) results for three methods across six datasets. Statistical significance was determined by one-sided Wilcoxon signed-rank test (deepBlink greater than) with **P < 1e−2, ****P < 1e−4. Size of test set: 129 smFISH, 105 SunTag, 64 Particle, 240 Microtubule, 240 Receptor and 240 Vesicle. Bold signifies the highest score
TrackMate | DetNet | deepBlink | ||||
---|---|---|---|---|---|---|
Real | smFISH | 0.865 ± 0.177 | **** | 0.442 ± 0.250 | **** | 0.905 ± 0.145 |
SunTag | 0.652 ± 0.328 | ** | 0.036 ± 0.040 | **** | 0.712 ± 0.279 | |
Synthetic | Particle | 0.941 ± 0.008 | **** | 0.828 ± 0.014 | **** | 0.944 ± 0.008 |
Microtubule | 0.380 ± 0.228 | **** | 0.298 ± 0.149 | **** | 0.637 ± 0.261 | |
Receptor | 0.606 ± 0.344 | **** | 0.517 ± 0.258 | **** | 0.682 ± 0.310 | |
Vesicle | 0.459 ± 0.198 | **** | 0.520 ± 0.245 | **** | 0.732 ± 0.259 | |
Average | 0.651 ± 0.214 | 0.440 ± 0.159 | 0.769 ± 0.210 |