Fig. 7. The urine score can measure and distinguish between clinically relevant transplant parameters.

Fig. 7.

(A) In the total cohort of 364 transplant samples, there were 160 clinically-indicated biopsies, of which 90 had a urine score above the rejection threshold and 70 below the threshold. Out of the 204 protocol biopsies, 71 had a score above the rejection threshold and 133 below. The breakdown of different biopsy diagnoses paired with the sample are shown in the figure as percentages. (B) Accuracy tables for biopsy (for-cause versus protocol) and the Q-Score (score <32 versus ≥32) for AR and STA classification.