Table 3.

Number of specimens regarding the fracture mode for each temporary cement

Cement Adhesive cement fracture on the abutment (I) Adhesive/cohesive cement fracture on the abutment (II) Cohesive cement fracture (III) Adhesive cement fracture at the crown (IV) Adhesive/cohesive cement fracture at the crown (V)
Implantlink without TC 3 3 4 0 0
Implantlink with TC 1 3 3 0 0
Harvard without TC 5 3 1 1 0
Harvard with TC 1 5 3 1 0
Temp Bond NE without TC 0 1 8 0 1
Temp Bond NE with TC 0 1 5 1 1