Skip to main content
. 2021 Jun 8;12(13):2421–2436. doi: 10.1021/acschemneuro.1c00151

Table 1. Absolute Values Calculated for Kinetic Parameters in Macroscopic Current Analysisa.

kinetic parameter WT (EXP) n = 14 α1 G258V n = 6 β2 L296V n = 7 α1 L300V n = 12 WT (LC) n = 10 β2 G254V n = 10
rise time [ms] 0.41 ± 0.04 0.66 ± 0.04* 0.64 ± 0.06* 0.60 ± 0.07* 1.83 ± 0.19 1.50 ± 0.11
    p < 0.001 p = 0.003 p = 0.037    
FR 10 0.30 ± 0.02 0.56 ± 0.04* 0.43 ± 0.04* 0.31 ± 0.02 0.60 ± 0.06 0.45 ± 0.04*
    p< 0.001 p = 0.005     p = 0.047
FR 300 0.15 ± 0.02 0.26 ± 0.03* 0.29 ± 0.03* 0.17 ± 0.01 0.42 ± 0.04 0.28 ± 0.03*
    p = 0.005 p < 0.001     p < 0.001
FR 500 0.13 ± 0.06 0.18 ± 0.03 0.26 ± 0.03* 0.13 ± 0.01 0.36 ± 0.04 0.26 ± 0.02*
      p < 0.001     p = 0.030
τfast [ms] 2.27 ± 0.19 3.71 ± 0.18* 4.90 ± 0.61* 2.42 ± 0.10 4.82 ± 0.26 2.94 ± 0.10*
    p < 0.001 p < 0.001     p = 0.001
τslow [ms] 127.98 ± 9.92 247.19 ± 31.88* 313.09 ± 51.82* 210 ± 26.47* 294.69 ± 51.77 158.48 ± 14.34*
    p < 0.001 p = 0.001 p = 0.021   p = 0.018
%Afast 0.70 ± 0.02 0.42 ± 0.04* 0.61 ± 0.04* 0.69 ± 0.02 0.38 ± 0.10 0.64 ± 0.07*
    p < 0.001 p = 0.042     p = 0.007
%Aslow 0.15 ± 0.03 0.41 ± 0.01* 0.15 ± 0.02 0.19 ± 0.02* 0.26 ± 0.03 0.15 ± 0.02*
    p < 0.001   p = 0.041   p = 0.007
%C 0.14 ± 0.02 0.15 ± 0.04 0.24 ± 0.04* 0.12 ± 0.01 0.36 ± 0.03 0.22 ± 0.02*
      p = 0.013     p < 0.001
deactivation τmean [ms] 383.87 ± 89.49 93.40 ± 21.36* 36.03 ± 5.91* 116.50 ± 10.60* 173.36 ± 37.31 375.42 ± 43.17*
    p < 0.001 p < 0.001 p < 0.001   p = 0.003
a

Significant changes relative to the respective WT control (EXP = excised-patch or LC = lifted-cell mode) are marked in bold with an asterisk (*), and the corresponding p value is disclosed; n = number of patches.