Table 1. Absolute Values Calculated for Kinetic Parameters in Macroscopic Current Analysisa.
kinetic parameter | WT (EXP) n = 14 | α1 G258V n = 6 | β2 L296V n = 7 | α1 L300V n = 12 | WT (LC) n = 10 | β2 G254V n = 10 |
---|---|---|---|---|---|---|
rise time [ms] | 0.41 ± 0.04 | 0.66 ± 0.04* | 0.64 ± 0.06* | 0.60 ± 0.07* | 1.83 ± 0.19 | 1.50 ± 0.11 |
p < 0.001 | p = 0.003 | p = 0.037 | ||||
FR 10 | 0.30 ± 0.02 | 0.56 ± 0.04* | 0.43 ± 0.04* | 0.31 ± 0.02 | 0.60 ± 0.06 | 0.45 ± 0.04* |
p< 0.001 | p = 0.005 | p = 0.047 | ||||
FR 300 | 0.15 ± 0.02 | 0.26 ± 0.03* | 0.29 ± 0.03* | 0.17 ± 0.01 | 0.42 ± 0.04 | 0.28 ± 0.03* |
p = 0.005 | p < 0.001 | p < 0.001 | ||||
FR 500 | 0.13 ± 0.06 | 0.18 ± 0.03 | 0.26 ± 0.03* | 0.13 ± 0.01 | 0.36 ± 0.04 | 0.26 ± 0.02* |
p < 0.001 | p = 0.030 | |||||
τfast [ms] | 2.27 ± 0.19 | 3.71 ± 0.18* | 4.90 ± 0.61* | 2.42 ± 0.10 | 4.82 ± 0.26 | 2.94 ± 0.10* |
p < 0.001 | p < 0.001 | p = 0.001 | ||||
τslow [ms] | 127.98 ± 9.92 | 247.19 ± 31.88* | 313.09 ± 51.82* | 210 ± 26.47* | 294.69 ± 51.77 | 158.48 ± 14.34* |
p < 0.001 | p = 0.001 | p = 0.021 | p = 0.018 | |||
%Afast | 0.70 ± 0.02 | 0.42 ± 0.04* | 0.61 ± 0.04* | 0.69 ± 0.02 | 0.38 ± 0.10 | 0.64 ± 0.07* |
p < 0.001 | p = 0.042 | p = 0.007 | ||||
%Aslow | 0.15 ± 0.03 | 0.41 ± 0.01* | 0.15 ± 0.02 | 0.19 ± 0.02* | 0.26 ± 0.03 | 0.15 ± 0.02* |
p < 0.001 | p = 0.041 | p = 0.007 | ||||
%C | 0.14 ± 0.02 | 0.15 ± 0.04 | 0.24 ± 0.04* | 0.12 ± 0.01 | 0.36 ± 0.03 | 0.22 ± 0.02* |
p = 0.013 | p < 0.001 | |||||
deactivation τmean [ms] | 383.87 ± 89.49 | 93.40 ± 21.36* | 36.03 ± 5.91* | 116.50 ± 10.60* | 173.36 ± 37.31 | 375.42 ± 43.17* |
p < 0.001 | p < 0.001 | p < 0.001 | p = 0.003 |
Significant changes relative to the respective WT control (EXP = excised-patch or LC = lifted-cell mode) are marked in bold with an asterisk (*), and the corresponding p value is disclosed; n = number of patches.