Cryo-EM data collection, refinement and validation statistics.

Reconstruction data mHsp60 (PSU COM) mHsp60 (NCCAT)
Data collection information
Electron microscope TFS Titan Krios TFS Titan Krios
Operation voltage (kV) 300 300
Electron detector Gatan K3 Gatan K3
Energy filter (slit width in eV) 30 no
Data collection software TFS EPU Leginon
Data collection mode counting Super-resolution counting
Nominal magnification 120,000 ×  81,000 × 
Pixel size in Å (super resolution) 0.84 1.069 (0.535)
Total accumulated dose (e2) 44 50–57
Data process statistics
Box size (pixel) 320 240
Number of particles 196,060 182,600
CTF estimation Gctf CTFFIND4
Data processing software RELION 3.1 RELION 3.1
Symmetry imposition C7 C7
B-factor applied (Å2) − 151 − 191
Final resolution (Å) 3.5 3.5
Combined B-factor (Å2) − 180
Combined resolution (Å) 3.4
EMDB code EMD-23217
Model refinement statistics
CCmasked (Model vs Data) 0.73
CCvolume (Model vs Data) 0.71
RMSD bond length (Å) 0.007
RMSD bond angles (°) 0.699
Ramachandran plot
Favored (%) 88.85
Allowed (%) 10.77
Outliers (%) 0.38
Clash score 12.51
PDB code 7L7S