Skip to main content
. 2021 May 16;22(7):77–92. doi: 10.1002/acm2.13262

Fig. 3.

Fig. 3

Relative IDD data for Geant4 calculations adjusted to fit measurements with a Stingray chamber (a) before correction and (b) after correction. The red points represent the dose measurements. The solid, dashed, and dotted lines represent IDDtotal (IDD12C + IDDfrag), IDD12C, and IDDfrag respectively. The correction parameters in Eqs. (10) and (11) are λ = 170 mm (before correction) and λ’=150 mm (after correction).