The sample codes, composition, and some characteristics of bioactive composite cryogels.

Samples a XG, wt.% PVA, wt.% Amount of Grape Pomace Extracts, v/v% SR b, g/g
CG 50 50 0 32.14 ± 1.22
CG.F10 50 50 10 21.92 ± 2.60
CG.F20 50 50 20 20.92 ± 1.71
CG.F30 50 50 30 15.80 ± 2.05
CG.M10 50 50 10 20.00 ± 0.94
CG.M20 50 50 20 16.55 ± 1.14
CG.M30 50 50 30 13.25 ± 0.88
CG.M40 50 50 40 11.19 ± 1.47

a The code sample of composite films includes the following: “CG” from composite gel; “F” or “M” from the variety of the grape pomace extract, Feteasca Neagra or Merlot. The final number from the sample codes represents the amount of extract entrapped within the composite matrices. All samples were prepared upon seven freeze-thawing cycles. b SR represents the swelling ratio and was evaluated by Equation (1) (see Section 4, Materials and Methods).