Table 6.

Comparison of previous studies with present study on accuracy of different formulae for the entire corneal curvature group and axial length groups

Flat K (<42D) Medium K (42D-46D) Steep K (>46D) Entire K Short AL (≤22 mm) Medium AL (>22.0-<24.0 mm) Long AL (>24.0 mm) Entire AL
Reitblat et al.[2] SRK-T - SRK-T - - - - -
Kuthirummal et al.[4] - - - - Barrett Barrett Barrett -
Connell and Kane[6] - - - - - Kane - -
Cooke and Cooke[16] - - - - Barrett and Olsen Barrett and Olsen - -
Zhang et al.[17] - - Barrett - - - - -
Wang et al.[18] - - - - - - Barrett -
Hoffer[19] - - - - Hoffer Q and Holladay 2 Hoffer Q and Holladay 1 SRK-T and Holladay 2 -
Savini et al.[20] - - SRK-T - - - - -
Kamiya et al.[21] - - SRK-T - - - - -
This study (±0-0.12D) SRK-T Holladay 1 and Hill RBF Kane Kane and Hill RBF Hoffer Q Hill RBF SRK-T Kane and Hill RBF

AL: Axial length