Table 5.
Properties | PCR | iiPCR | LAMP |
---|---|---|---|
Temperature | Cycles through 3 temperatures 55–95 °C |
Constant temperature drives temperature gradient 15–30 °C |
Constant temperature 60–65 °C |
Equipment | Thermocycler | Specialized reaction tube Fluorescence-based detector |
Heat source |
Field-deployable | No | Yes | Yes |
Reaction time | At least 90 min | ≤60 min | <30 min |
Sensitivity | Starts at nanograms | Starts at nanograms | Starts at femtograms |
Specificity | Requires specific primer design Prone to errors |
Requires specific primer design Prone to errors |
Tolerates combination of primer designs |
Visualization | Only through gel electrophoresis | Real-time available | Real-time available |
Template prep | Requires purification | Requires purification | Tolerates impurities |
Cost | $$$ | $$ | $ |