Skip to main content
. Author manuscript; available in PMC: 2021 Jul 23.
Published in final edited form as: Technology (Singap World Sci). 2020 Nov 5;8(1-2):27–36. doi: 10.1142/s2339547820500028

Table 1.

Time statistics of perfusion trends compared to baseline.

Perfusion metric Statistical test Baseline timepoint P value Significance
Injury Markers
*AST Paired t-test T = 6 hours 0.029 Yes
*ALT Paired t-test T = 6 hours 0.050 Yes
Resistance One-way ANOVA T = 6 hours 0.098 No
Perfusate potassium One-way ANOVA T = 6 hours 0.434 No
Functional Markers
Oxygen consumption One-way ANOVA T = 2 hours 0.609 No
Arterial (inflow) lactate One-way ANOVA T = 2 hours 0.053 No
Arterial (inflow) pH One-way ANOVA T = 2 hours 0.407 No
*Glucose One-way ANOVA T = 2 hours 0.014 Yes
*

(significant difference, p < 0.05)