Table 2.
Parametric values for the printhead and binder jetting.
| Parameters | Value | Significance |
|---|---|---|
| Desired Saturation | 90% | This value represents the theoretical void space that exists between powder particles that will be filled with binder |
| Drop Volume | 68.4 pL | Amount of binder per droplet. This must be calculated to achieve desired saturation. This is found via measurement. |
| Build Layer Thickness (Z layer spacing) | 50 μm | Build bed drops this distance between each layer followed by powder deposition. |
| X Jet Spacing | 254 μm | Distance between jets in the print head. |
| Y Print Speed | 150 mm/s | Printhead speed in the Y direction, which is calculated by Drop Spacing and Computed Drop Frequency. |
| Printhead Firing Frequency | 2505 Hz | Frequency of printhead firing binder jets. |
| Passes Per Jet Spacing | 4 | Number of necessary passes to print each layer. |
| X Drop Spacing | 63.5 μm | Distance between binder jets in the X direction. |
| Y Drop Spacing | 59.9 μm | Distance between binder jet deposition in the Y direction. |