Performance for classifying bone marrow edema from individual MR slices (%).

Accuracy Recall Precision Specificity NPV F1-Score
Ori data 83.45 85.13 81.90 82.72 87.03 82.68
(±3.37) (±8.26) (±7.56) (±7.08) (±5.59) (±4.92)
ROI patch 93.55 92.87 94.69 94.23 92.40 93.75
(±2.19) (±1.27) (±3.03) (±3.77) (±2.31) (±1.78)
ROI patch 93.80 93.35 94.70 94.24 92.87 93.95
(median filter) (±2.38) (±1.83) (±3.01) (±3.79) (±2.68) (±1.91)