Skip to main content
. 2021 Jul 5;11(7):1212. doi: 10.3390/diagnostics11071212

Table 6.

DenseNet201 activated feature based classification using 10-fold cross validation.

Method Accuracy (%) Sensitivity (%) Specificity (%) Precision (%) F1-Score (%)
LSVM 98.30 100 94.76 94.76 98.76
QSVM 98.61 100 95.71 97.98 98.98
Cubic–SVM 98.30 99.54 95.71 97.97 98.75
SVM–Medium Gaussian 98.45 100 95.24 97.76 98.87