Table 6.
PICA efficiency simulations and measurements at 4, 7, and 10 GHz for both ink formulations.
| Frequency (GHz) | 4 | 7 | 10 | ||
|---|---|---|---|---|---|
| Efficiency (%) |
Simulated | CNTs/CNC—1:1 | 26 | 37 | 47 |
| CNTs/CNC—1.5:1.5 | 27 | 39 | 50 | ||
| Measured | CNTs/CNC—1:1 | 20 | 25 | 34 | |
| CNTs/CNC—1.5:1.5 | 22 | 27 | 40 | ||