Skip to main content
. Author manuscript; available in PMC: 2022 Sep 1.
Published in final edited form as: IEEE Trans Biomed Eng. 2021 Aug 19;68(9):2764–2775. doi: 10.1109/TBME.2021.3054248

TABLE VIII.

Summary of the lesion case-based classification accuracy, sensitivity, specificity, and odd ratio of using 5 SVMs trained using different groups of optimized features.

Feature
sub-
group
Accuracy
(%)
Sensitivity
(%)
Specificity
(%)
Odds
Ratio
Original features 69.3 62.0 75.0 4.85
NMF 72.4 63.1 79.5 6.61
Chi2 70.9 63.0 77.1 5.67
PCA 72.8 68.0 76.6 6.87
RPA 75.2 70.2 79.0 8.86