Skip to main content
. Author manuscript; available in PMC: 2022 Jan 1.
Published in final edited form as: Meas Sci Technol. 2021;32(7):10.1088/1361-6501/abdae3. doi: 10.1088/1361-6501/abdae3

Table 1:

Test positions for point-to-point distance measurement evaluation [116]

Test # x1n x1z x2 x3 x4 x5n x5z x6 x7 x8x x8y x9n x9z x10 x11a x11b x12a x12b
1 0 0 −1 0 0 0 0 0 0 3 0 0 0 −1 0 −4 0 0
2 1 0 0 0 0 3 0 0 0 0 0 3 0 −1 0 0 0 4
3 0 1 −1 0 0 1 2 0 −2 2 0 1 0 −2 0 −3 0 2
4 0 −1 −1 0 0 1 −2 0 2 2 0 1 0 −2 0 −3 0 2

Note: Rows represent test positions and the columns represent model parameters. Rows 1 through 4 represent symmetric horizontal, vertical, left-diagonal and right-diagonal lengths, respectively. Columns represent model parameters, see [116] for explanation.