Table 2.

Measurement parameters for air sensor performance (Penza, 2018).

Transducer Sensitivity Selectivity Stability Limit of Detection Open Questions

Electrochemical High Variable Improved ppb Interference, calibration, signal processing
Spectroscopic and NDIR High Variable Low ppm Interference, calibration, signal processing
Photo-Ionization Detector High Low Improved ppb Interference, calibration, signal processing
Optical Particulate Counter High Improved Improved μg/m3 Interference, calibration, signal processing
Metal Oxides High Variable Low ppb Interference, calibration, signal processing
Pellistors High Low Improved ppm Interference, calibration, signal processing