Table 6.

Summary of PM2.5 sensor performance attributes from the subject matter expert discussion on Day 3.

Technology Attribute Minimum Acceptable Value/Range (count)a Estimated Minimum Acceptable Value/Range

Accuracy 10% (2) Range: 10%–100%
15% (2)
20% (1)
30% (1)
50% (1)
20–50% (1)
20–30% (2)
Factor of 2, 100% (1)
Median: 25%
Bias 2.5% (1) Range: 1 μg/m3 – 5 μg/m3
10% (2) or 2.5%–50%
20% (1)
35% (1)
50% (1)
1 μg/m3 (1) 3 μg/m3 (1)
5 μg/m3 (1)
Median: 2 μg/m3 or 15%
Correlation r = 0.84 (1) Range: r = 0.84–0.95
r = 0.87 (1) r = 0.89 (2) r = 0.95 (1) Median: r = 0.89
Detection Limit 1 μg/m3 (1) Range: 2–4 μg/m3
2 μg/m3 (1)
4 μg/m3 (1)
Median: 2 μg/m3
Precision 10% (1) Range: 10%–50%
20% (2)
25% (1)
30% (1)
50% (1)
Median: 23%
a

Numbers (X) represent the count of SEs who suggested each metric.

(Note: The listed sensor performance values should not be considered suggestive about any specific US EPA recommended means of establishing such a value).