Skip to main content
. 2021 Jul 12;10:e69482. doi: 10.7554/eLife.69482

Table 5. Liposome efflux experiments: compiled results from all replicates.

Construct Anion Figure Rate (ions/s): Prep 1 Rate (ions/s): Prep 2 Mean ± SEM
Ec2 WT F- 1-S1 >104, >104 >104, >104 >104
Ec2 C74A F- 1-S1 >104, >104 >104, >104 >104
Ec2 WT F- 2a >104, >104 >104, >104 >104
Ec2 S81A F- 2a >104, >104, >104 >104, >104, >104 >104
Ec2 S81T F- 2a <100, <100 <100, <100 <100
Ec2 S81C F- 2a <100, <100 <100, <100 <100
Ec2 S81A/S82A F- 2a 8860, 6400 9640, 7840, 8860 8320 ± 560 ions/sec
Ec2 S81A/S82A Cl- 2-S2 <50, <50 <50, <50 <50
Bpe S83A/T84A Cl- 2-S2 <50, <50 <50, <50 <50
Bpe T39V F- 3-S1 <100, <100 <100, <100 <100
Bpe T39S F- 3-S1 >104, >104, >104 >104, >104 >104
Bpe T39C F- 3-S1 <100, <100, <100 <100, <100 <100
Bpe T39A F- 3-S1 <100, <100 <100, <100 <100
Bpe T39N F- 3-S1 <100 <100, <100 <100
Bpe E88A F- 3-S1 >104, >104 >104, >104, >104 >104
Bpe E88Q F- 3-S1 >104, >104 >104, >104, >104 >104
Bpe E88D F- 3-S1 >104, >104 >104, >104, >104 >104
Bpe E88K F- 3-S1 <100 <100, <100 <100
Bpe Y104F F- 3-S1 >104, >104, >104 >104, >104 >104
Bpe Y104S F- 3-S1 <100, <100, <100 <100, <100 <100
Bpe Y104H F- 3-S1 <100, <100 <100, <100 <100
Bpe Y104I F- 3-S1 <100, <100 <100 <100
Bpe I50W F- 1-S1 600, 720, 960 650, 550, 720 700 ± 60 ions/sec
Bpe Y104F Cl- 4-S1 <50, <50 <50, <50 <50
Bpe T39S Cl- 4-S1 <50, <50 <50, <50 <50
Bpe E88Q Cl- 4-S1 <50, <50 <50, <50 <50
Bpe E88A Cl- 4-S1 <50, <50 <50, <50 <50