Table 1.
Speck assay 81,000 high-throughput screening metrics.
Metric | Specification (Spec) | Average (across all plates) | SD |
---|---|---|---|
Robust Z′ (positive control, MCC950 5 µM) | > 0.6 | 0.9 | 0.1 |
Robust Z′ (positive control, MCC950 50 nM = IC50) | > 0.2 | 0.6 | 0.2 |
SSMD | > 5 | 24 | 13.6 |
% CV (negative control, maximum speck number) | < 10 | 5 | 2.3 |
Assay plates were subjected to quality control analysis, evaluating the performance of each plate using positive (MCC950 50 nM and 5 µM) and negative (vehicle, DMSO) controls. The quality assay control acceptance criteria selected were robust Z′ > 0.6 (MCC950 5 µM; maximum speck number reduction), robust Z′ > 0.2 (MCC950 50 nM = IC50). SSMD > 5, % CV < 10% (negative control, maximum speck number). Screening metric averages and standard deviations across plates are shown.