Skip to main content
. 2020 Sep 23;25(8):2011–2018. doi: 10.1007/s11605-020-04802-4

Table 3.

Polyp detection

Variable Traditional colonoscopy (n = 150) AI-assisted colonoscopy (n = 150) p value
Patients with at least one polyp, n (PDR) 51 (34.0%) 58 (38.7%) < 0.001
Patients with at least one diminutive polyp, n (%) 45 (30.0%) 52 (34.7%) < 0.001
Patients with at least one Paris type 0-IIa polyp, n (%) 39 (26.0%) 48 (32.0%) < 0.001
Polyps detected, n 80 105 0.020
Polyps detected, by dimension
  < 6 mm, n 69 91 < 0.001
  ≥ 6 mm, n 11 14 0.319
Polyps detected, by typea
  0-IIa, n 61 87 0.010
  0-Is, n 8 5 0.181
  0-Ip, n 11 13 0.319

aParis classification