Table 15. Results of NIST test suite for proposed method.
Test ID | Test name | Proposed method p-values | Result |
---|---|---|---|
1 | frequency | 0.52137 | Pass |
2 | Block frequency test | 0.49166 | Pass |
3 | Runs test | 0.52343 | Pass |
4 | Longest runs of 1’s | 0.51692 | Pass |
5 | Non-overlapping (m = 4, B = 0001) | 0.43175 | Pass |
6 | Non-overlapping (m = 4, B = 0011) | 0.46749 | Pass |
7 | Non-overlapping (m = 4, B = 0111) | 0.44740 | Pass |
8 | Non-overlapping (m = 4, B = 1000) | 0.46273 | Pass |
9 | Non-overlapping (m = 4, B = 1100) | 0.45967 | Pass |
10 | Non-overlapping (m = 4, B = 1110) | 0.48632 | Pass |
11 | Overlapping templates | 0.565576 | Pass |