Limit of detection at 95 and 50% confidence interval (LOD95% and LOD50%) for SARS-CoV-2 and surrogates PEDV and E229 on glass, steel and plastic surfaces following the selected sampling Method A coupled with MAX RNA extraction procedure.

Inoculated virus Glass
Steel
Plastic
Positivesa LOD95%b LOD50%b Positives LOD95% LOD50% Positives LOD95% LOD50%
SARS-CoV-2 (gc/4 cm2) 5.10 × 104 6/6 3.31 × 102 7.65 × 101 6/6 2.18 × 102 5.03 × 101 6/6 6.37 × 102 1.47 × 102
5.10 × 103 6/6 6/6 6/6
5.10 × 102 6/6 6/6 6/6
5.10 × 101 2/6 3/6 0/6
5.10 × 100 0/6 0/6 0/6
E229 (PCRU/4 cm2) 2.28 × 105 6/6 1.60 × 103 3.70 × 102 6/6 4.92 × 103 1.14 × 103 6/6 4.65 × 103 1.08 × 103
2.28 × 104 6/6 6/6 6/6
2.28 × 103 6/6 5/6 4/6
2.28 × 102 2/6 0/6 2/6
2.28 × 101 0/6 0/6 0/6
PEDV (PCRU/4 cm2) 1.42 × 104 6/6 3.60 × 102 8.34 × 101 6/6 6.94 × 102 1.61 × 102 6/6 1.01 × 103 2.33 × 102
1.42 × 103 6/6 6/6 6/6
1.42 × 102 4/6 3/6 2/6
1.42 × 101 1/6 0/6 0/6
1.42 × 100 0/6 0/6 0/6