Skip to main content
. 2021 Jul 20;8:637747. doi: 10.3389/fmed.2021.637747

Table 2.

Incidence of potentially high risk of ventilator-induced lung injury.

Mild ARDS (n = 8) Moderate or severe ARDS (n = 12)
Best-oxygenation Best-compliance ARDSnet low PEEP table Best-oxygenation Best-compliance ARDSnet low PEEP table
Pplat > 30 cm H2O n (%) 1 (12.5%) 1 (12.5%) 2 (25.0%) 8 (66.7%)* 1 (8.3%) 8 (66.7%)
ΔP > 15 cm H2O n (%) 3 (27.5%) 2 (25.0%) 3 (27.5%) 10 (83.3%) 5 (41.7%) 8 (66.7%)
Mechanical Power > 25 J/min n (%) 2 (25.0%) 0 1 (12.5%) 6 (50.0%)* 0 7 (58.3%)

Pplat, plateau pressure; ΔP, driving pressure.

*

p < 0.05 by Fisher's exact tests in best-oxygenation PEEP vs. best-compliance PEEP.

p < 0.05 by Fisher's exact tests in ARDSnet low PEEP table vs. best-compliance PEEP.