Skip to main content
. 2021 Jul 20;41(7):1044–1049. [Article in Chinese] doi: 10.12122/j.issn.1673-4254.2021.07.11

2.

两组患者PCI前后IVUS检测结果比较

Comparison of IVUS results between the two groups before and after PCI (Mean±SD)

Items SB group (n=52) CB group (n=59) t P
IVUS test before PCI
  Intimal calcification radian (°) 319.1±14.3 319.9±16.1 -0.288 0.774
  Calcified lesion total length (mm) 14.16±4.06 15.09±3.42 -1.304 0.195
  Reference vessel diameter (mm) 2.79±0.37 2.70±0.47 1.136 0.259
  Minimum lumen diameter (mm) 1.00±0.17 0.99±0.15 0.579 0.564
  Minimum lumen cross-sectional area (mm2) 1.01±0.12 0.97±0.16 1.499 0.137
  Lumen cross-sectional area stenosis degree (%) 83.7±3.7 84.9±3.9 -1.699 0.092
PCI stent application
  Number of stents placed/Target blood vessels (number) 1.85±0.36 1.76±0.43 1.108 0.270
  Stent length/Target blood vessels (mm/single) 37.2±4.3 35.9±3.8 1.605 0.111
IVUS test after PCI
  Minimum stent lumen diameter (mm) 2.52±0.41 2.66±0.30 -2.140 0.035
  Minimum lumen cross-sectional area in the stent (mm) 5.35±0.60 5.63±0.72 -2.207 0.029
  Residual stenosis of lumen cross-sectional area (%) 13.4±2.1 11.7±2.3 3.996 0.000
  Immediate lumen diameter acquisition (mm) 1.40±0.30 1.60±0.26 -3.873 0.000
  Immediate lumen cross-sectional area acquisition (mm2) 3.78±0.62 4.80±0.53 -9.286 0.000
Lesions residual stenosis < 10 % [n (%)] 3(5.8) 15(25.4) 7.859 0.005