Abstract
Introduction
As the demand for rehabilitation in orthopaedics increases, so too has the development in advanced rehabilitation technology. However, to date, there are no review papers outlining the broad scope of advanced rehabilitation technology used within the orthopaedic population. The aim of this study is to identify, describe and summarise the evidence for efficacy for all advanced rehabilitation technologies applicable to orthopaedic practice.
Methods
The relevant literature describing the use of advanced rehabilitation technology in orthopaedics was identified from appropriate electronic databases (PubMed and EMBASE) and a narrative review undertaken.
Results
Advanced rehabilitation technologies were classified into two groups: hospital-based and home-based rehabilitation. In the hospital-based technology group, we describe the use of continuous passive motion and robotic devices (after spinal cord injury) and their effect on improving clinical outcomes. We also report on the use of electromagnetic sensor technology for measuring kinematics of upper and lower limbs during rehabilitation. In the home-based technology group, we describe the use of inertial sensors, smartphones, software applications and commercial game hardware that are relatively inexpensive, user-friendly and widely available. We outline the evidence for videoconferencing for promoting knowledge and motivation for rehabilitation as well as the emerging role of virtual reality.
Conclusions
The use of advanced rehabilitation technology in orthopaedics is promising and evidence for its efficacy is generally supportive.
Keywords: Rehabilitation, Technology, Orthopaedics, Telerehabilitation
Introduction
With an ageing population, the number of patients affected by orthopaedic conditions that either require rehabilitation alone or surgical intervention and subsequent rehabilitation are on the rise [1, 2]. As the demand for rehabilitation increases, advanced rehabilitation technology has also developed, but its role and efficacy are not always appreciated by surgeons or therapists. Rehabilitation in orthopaedics often aims to improve range of motion (ROM) and muscle strength around joints. Devices with sensors [3] or robotic technology [4] that enable quantitative measurements of these parameters in three dimensions have been designed and applied in the clinical setting. Feedback and patient self-monitoring have been strongly associated with improved outcomes [5], and these technologies make monitoring and feedback more accessible.
Some advanced rehabilitation technology is bulky, costly and complex and mainly useful for rehabilitation in hospital. However, rehabilitation after many surgical interventions takes place in a patient’s own home [6]. Adherence to home musculoskeletal rehabilitation protocols has been shown to be poor with some studies reporting rate of non-compliance to be 50–65% [7]. With the accessibility of high-speed Internet, teleconferencing has been made possible [8] improving contact in orthopaedic rehabilitation and potentially improving compliance. The use of gaming consoles and other widely available gaming hardware [9] to interact with patients may also improve compliance. In addition, use of this technology may aid therapists to diagnose, treat, and monitor patients’ progress remotely. The therapist may then ensure correct performance of exercises and increase motivation resulting in improved patient adherence [10]. Use of advanced rehabilitation technology in this way enhances home-based rehabilitation and may be a time and cost-efficient alternative to conventional clinical or home-based face-to-face sessions.
Although there has been growing interest in the use of advanced rehabilitation technologies in orthopaedics, an initial scoping review of the literature failed to identify a paper offering a broad overview of this technology used within an orthopaedic population. Therefore, the purpose of this narrative review is to explore the broad variety of technologies that are currently being used in orthopaedic rehabilitation and determine the extent to which these technologies can support and complement traditional services such as physiotherapy.
Materials and methods
A literature search of journal articles using the PubMed (MEDLINE) and EMBASE databases was conducted in September 2019. No date restrictions were placed. Relevant literature describing rehabilitation technology utilized in orthopaedics was identified from the above appropriate clinical databases and a narrative review was undertaken.
Rehabilitation technology
This review paper considers advanced rehabilitation technology into two sections: hospital-based rehabilitation and home-based rehabilitation (see Table 1 for summary). It describes each advanced technology and details the current evidence for its use.
Table 1.
Summary of advanced rehabilitative technologies. TKR, total knee replacement; 3D, 3-dimensional; ROM, range of movement
| Primary location of use | Technology | Features |
|---|---|---|
| Hospital-based technologies | Continuous passive motion | Well established after TKR. Has also been tried in the home setting. |
| Robotic devices | Support body weight, particularly after spinal cord injury. | |
| Electromagnetic sensors | Measures 3D kinematics, but cumbersome outside the gait lab. | |
| Home-based technologies | Inertial sensors | Collect 3D motion data. Inexpensive and portable. |
| Software applications | Can be used on a smartphone or tablet. Used for measurement of movement and patient feedback. | |
| Commercial gaming technology | Detects subtle changes in balance, co-ordination and ROM during functional activities. | |
| Videoconferencing | Allows remote diagnosis, treatment and monitoring. |
Hospital rehabilitation
Continuous passive motion (CPM)
The use of CPM in orthopaedic rehabilitation has been around for two decades and is most commonly reported following total knee replacement (TKR) and has been primarily advocated to improve knee flexion recovery [11, 12]. Naylor et al. reported that greater knee ROM at discharge after TKR was a significant predictor of improved ROM after rehabilitation [13]. A recent meta-analysis provided statistically significant, moderate evidence, indicating that CPM reduced pain, restored knee ROM and enhanced functional recovery after TKR regardless of follow-up duration [14]. It has been suggested that CPM leads to positive biological effects on tissue healing, oedema and haemarthrosis [11, 15]. CPM is widely used in hospitals in the post-operative period allowing therapists to streamline their workload and improve their capacity to see other patients [6]. CPM has also been used for the rehabilitation of other knee conditions such as ligament reconstruction surgery in both adults [16] and children [17]. CPM is also being trialled for the treatment of other joints, such as the elbow [18] and shoulder [19], but so far, no advantage to CPM has been definitively reported. Smart, user-friendly programmable machines are becoming the norm [20].
Electromagnetic sensors
The electromagnetic tracking system (ETS) is a six degrees-of-freedom measuring device that simultaneously records the three-dimensional (3D) position and orientation of multiple electromagnetic sensors attached to body segments using a transmitter [3, 21, 22]. The reliability of ETS for measuring kinematics (e.g. ROM) of the upper and lower limbs has been reported [3, 22]. Nakagawa et al. demonstrated that it can be used to accurately evaluate 3D kinematics such as single leg squat and stepping [21]. The ETS may also be used to measure kinematic changes in a patient over time, which is useful for assessment of rehabilitation interventions. The disadvantage of ETS is that it is cumbersome and unable to be easily used outside of a laboratory or clinical-based setting. Recently, however, a more clinically friendly device that measures knee kinematics using only two electromagnetic sensors (on the thigh and shank) has been reported [23, 24]. This compact ETS also enables quantitative evaluation of the pivot shift test pre- and post-anterior cruciate ligament (ACL) reconstruction.
Robotic devices
Rehabilitation in patients with spinal cord injury (SCI), who have reduced or absent sensorial input and motor output, is challenging [25]. Particularly, the support of the patient’s body weight during rehabilitation leads to physical exhaustion of the therapist [26]. To overcome this, robotic supportive devices have been developed that may reduce the physical demands on the therapist [26, 27]. Several studies have demonstrated that robotic-assisted gait training in SCI patients promotes body compensation and neuroplasticity, leading to improvements in cardiorespiratory, urinary, musculoskeletal, neuronal and somatosensory systems [28–32]. A systematic review evaluating robotic assisted gait for SCI also showed similar results [26].
Recently, portable robots such as the ARGO (ARGO Xtreme Terrain Robotics, ON, Canada), EKSO (EKSO Bionics, CA, USA), Indego (Parker Hannifin Corp., OH, USA), ReWalk (ReWalk Robotics, Inc., MA, USA) and WPAL (Fujita Health University, Aichi, Japan) have also been developed, and can perform gait training not only indoors but also outdoors. Hybrid Assistive Limb (HAL; University of Tsukuba, Ibaraki, Japan) has a hybrid system allowing both a voluntary and an autonomous mode of action to support gait training. HAL uses control algorithms and supporting devices that control each knee and hip separately. A systematic review reported that although HAL had beneficial effects on gait, function and independence in walking, no study provided conclusive data on differences between HAL gait-training compared to the other forms of gait-training [33]. On the other hand, Cheung et al. performed a meta-analysis of randomised controlled trials (RCTs) or quasi-RCTs that compared robotic-assisted lower limb training to a control of other treatment approaches or no treatment in SCI patients [4]. They concluded that the robotic-assisted training group showed better improvement in walking independence and endurance than other training methods.
The effect of robotic devices on upper limb rehabilitation in SCI patients is less established. Zarffa et al. reported no difference in the improvement in functional scores for patients receiving Armeo Spring® (Hocoma AG, Switzerland) training on one arm compared to the arm that did not have robotic-assisted rehabilitation, both at discharge and follow-up assessment [34]. To date, only a few studies have evaluated the effects of upper limb robot training after SCI and the evidence for their use is not robust. However, the use of upper extremity robotic rehabilitation devices in persons with SCI has gained increasing research interest, with aims to achieve enhanced functional ability via promotion of neuroplasticity [35].
Koller-Hodac et al. introduced a robot-assisted knee device that can be used at home to acquire a full ROM and joint flexibility after knee surgery [1]. A narrative review by Sicuri et al. suggested that it was reasonable to consider robotic rehabilitation of the shoulder for instability, stiffness, joint replacement, rotator cuff tear or other tendon ruptures [36]. A single-joint training robot, NeXOS (The Nexus Project, University of Abertay Dundee, UK; Bradley et al. [37]) was designed as a prototype to aid individualised lower limb rehabilitation, allowing progression from passive motion, through to active-assisted and on to resistance training. The automated system was also designed to record the patient’s movement, enabling the therapist to comprehensively analyse the effectiveness of exercises and adjust these as required for optimal joint recovery. Various other single joint training robots have been designed [38], but there are few clinical outcome studies to guide specific recommendations for their use in the clinical setting.
Robotic devices face a number of challenges including the pressure of the suit in certain areas, skin irritation, training-related pain, excessive energy consumption due to device use and high costs [26, 33]. Using robotic devices for rehabilitation after SCI may improve motor learning and promote neuroplasticity, possibly reducing secondary complications. This is a very active area of research and development, and it is likely that we will continue to see rapid growth in this field.
Home-based rehabilitation
Inertial sensors
Inertial sensors such as accelerometers, magnetometers and gyroscopes collect 3D motion data, which they communicate to a computer for analysis by accompanying software. This allows them to be used to accurately measure and assess the movement of a patient’s joint during a variety of functional exercises [39]. Saber-Sheikh et al. compared an inertial sensor system (utilising a combination of accelerometers, magnetometers and gyroscopes) to an ETS system to determine their relative abilities to evaluate functional activities such as walking [40]. The accuracy of the two methods were comparable. However, the inertial sensor system had the advantage that it was relatively inexpensive, portable and user-friendly. The inertial sensor system can feasibly be used in a patient’s home or workplace, rather than its use being confined to the laboratory or clinical environment. Kumar et al. demonstrated comparable ROM measurements between a wireless wearable automated inertial sensory system and traditional goniometry [41]. They proposed that the measurements recorded by the sensor system were more reliable, as they were not subject to the variability or subjectivity of practitioner’s use of the goniometer. The combination of both symptomatic and asymptomatic participants and variety of upper and lower extremity applications of the inertial sensors in their series demonstrates that inertial sensor technology is an effective method of quantifying dynamic ROM. However, Tulipani et al. suggested that the inertial sensor system overestimated lumbar flexion compared to the motion camera system [42]. This loss of accuracy may be due factors such as position of sensor placement, reliability of skin attachment or an interaction effect with the sensors. This underlines the importance of standardisation of sensor placement with reliable skin attachment skills together with improved inertial sensor algorithms to optimise the accuracy of the system. The studies cited above show that inertial sensors are useful to assess the impact of treatment modalities, but do not demonstrate their use which delivers improved outcomes.
Application software (Apps)
There are many medical Apps available, with some offering knowledge of medical conditions, anatomy, drug information or other treatments [43]. The reliability and validity of Smartphone Apps for measuring ROM or position sense in different joints has been explored in several studies including the cervical spine [44], lumbar spine [45], shoulder [46], elbow [47], knee [48] and ankle [49]. In addition to static ROM evaluation, smartphone-based accelerometers have been deemed to be an equally valid way of measuring dynamic knee ROM compared with a laboratory-based isokinetic dynamometer [50]. Hoshino et al. created an iPad (Apple Inc., Cupertino, CA) App that can process video images and provide data on the translation of the lateral compartment of knee in almost real time [51]. They demonstrated the potential of this App to classify the pivot shift in ACL-deficient patients [51, 52]. Matera et al. combined the accelerometer with smartphone global positioning system (GPS) to create an App that is able to detect, measure and record essential movements of the hand and wrist [43] that can automatically be sent to a medical professional at the end of a therapy session. Twenty participants underwent a four week wrist motion rehabilitation using this App after wrist surgery, which included plate fixation of distal radius fractures and arthroscopic repairs of triangular fibrocartilage complex. They demonstrated significantly improved ROM in every plane of wrist motion.
Apps are also useful for patient feedback. One technology that provides real-time feedback is a sensor called BandCizerTM (BandCizer Aps, Odense, Denmark) for elastic band exercises. It can quantify contraction time, the number of repetitions performed and the force used to stretch the elastic band by measuring the thickness of the band [53]. BandCizerTM can send data to an iPad, and the BandCizerTM App provides users with real-time feedback on exercises [53, 54]. Rathleff et al. reported that 40 adolescents with patellofemoral pain were randomized to treatment with real-time BandCizerTM-iPad feedback on contraction time or not. The App significantly improved compliance to the rehabilitation [55]. As elastic exercise bands are a versatile tool used for a range of upper and lower extremity exercises, BandCizerTM application could be utilised across multiple areas of orthopaedic physiotherapy rehabilitation [56].
However, Stove et al. emphasised that subtle variations exist in the quality of measurements depending on the smartphone manufacturer and also that updates of application software complicate the validity of the findings and may lead to inconsistencies in the assessment of measurement such as ROM [50]. Therefore, before clinical utilisation, the accuracy of each application needs to be evaluated and this should be repeated each time the software is updated.
Videoconferencing
Videoconferencing (VC) has the potential to play an important role in the management of orthopaedic patients. VC could allow therapists to diagnose, treat and monitor patients’ progress remotely as telerehabilitation in orthopaedic setting.
Eriksson et al. investigated patients’ experiences of participating in therapy via VC at home for 2 months after shoulder joint replacement [10]. This study reported that the access to the guided exercises via VC and the immediate feedback from the physiotherapist led to better knowledge about the body and the surgery, and also improved motivation for daily exercises. Furthermore, patients saw their therapist as expert and problem-solver in the first phase after the surgery allowing them to transition from being dependent and passive, to being independent and active whilst remaining at home.
Tousignant et al. reported on satisfaction with VC for patients following a RCT post TKR [8]. Although high satisfaction rates were noted with the technology, no significant difference was observed when VC was compared to traditional face-to-face rehabilitation. The same research group conducted semi-structured interviews about patients’ perceptions regarding telerehabilitation services [2] and reported that patients were satisfied with most of the aspects of their experience including access to services, their relationship with their therapist, the exercises program, the technology and the support provided by the technical team.
VC promotes the relationship between patients and therapists, knowledge and motivation for rehabilitation, and may reduce costs [57]. However, a recent systematic review concluded that although VC may be acceptable to patients, the day to day workability of VC in clinical practice from a clinician perspective is not always practical [58].
Commercial gaming technology
Commercially available gaming systems (CAGS) can detect subtle changes in balance, coordination, strength and ROM of a joint during functional activities [59]. CAGS may serve as a relatively inexpensive and clinician-friendly tool to assess objective functional measurements of patients. CAGS have been reported to promote motivation for therapeutic activities [60] and are an enjoyable method of encouraging physical exercise [61]. The most commonly described CAGS in the rehabilitation setting are the Nintendo Wii with Balance Board (WBB) (Nintendo, Kyoto, Japan) and the Microsoft Xbox with Kinect (Microsoft, Redmond, WA, USA). They utilise several different technologies including integrated accelerometers, infrared detection and movement tracking. Users can access a number of software applications for balance and motion training. The CAGS can also be used to assess postural control and general quality of motion while performing various movement tasks [59]. These devices have the advantage of being marker-less and portable, able to be used in the outpatient clinic, rehabilitation room and at home [62]. CAGS can use therapeutic training protocols that track a patient’s progress, reporting on objective functional measures during rehabilitation stages.
Many studies have shown Microsoft Xbox with Kinect to have an excellent correlation and reliability when compared to a gold-standard motion detection system such as the Vicon MZ motion analysis system (Kverneland Group UK Ltd, St Helens , UK) [63, 64]. However, the Kinect accuracy is reported to be dependent on movement and user position: e.g., the accuracy decreases when the user is sitting [65]. Wochatz et al. evaluated the reliability and validity of the Kinect in lower extremity rehabilitation exercises and reported that the variability was acceptable for joint angles and joint position during the squat, but not during the lunge [62]. Furthermore, there are problems reported with the accuracy of hand tracking [66]. Notwithstanding these limitations, a systematic review of motor rehabilitation using Kinect demonstrated improvements in clinical outcomes such as balance, posture, sensory information and ROM [66].
Yamada et al. reported that the score of Wii Fit (Nintendo, Kyoto, Japan) and Basic Step game correlated with Dual Task Lag of Timed Up-and-Go in older women, which demonstrated association with a real-life outcome [67]. A RCT study showed that Nintendo Wii Fit program versus the conventional rehabilitation after ACL reconstruction had comparable result for knee strength, balance, proprioception, coordination and response time at 8 and 12 weeks [68]. In another RCT study on TKR patients, the rehabilitation using Wii Fit achieved the same ROM, balance and function as the conventional exercise at discharge [9].
CAGS have the potential to make an important contribution in orthopaedic rehabilitation but their role in this context is still in development. Whilst most studies are favourable, some studies have not shown the effectiveness of CAGS when compared to the gold standard [69]. Strong conclusions regarding the reliability and validity of CAGS in the orthopaedic setting cannot be made at this stage [59].
The future
Many advanced rehabilitation technologies relevant to orthopaedics are still in development. Virtual reality (VR) technology, which includes an interactive computer environment or games that appear and feel real may also have a role. In physical rehabilitation, VR can be used to personalise treatment, motivate patients, improve compliance and track progress. Currently, there is a lack of strong evidence to support its use. Clinical trials have assessed VR effectiveness in patients with orthopaedic pathology such as ACL injury, frozen shoulder and chronic neck pain. Most of them used off-the-shelf console games such as Nintendo Wii Fit, making it difficult to differentiate from rehabilitation using CAGS [70].
Electromyography (EMG) muscle stimulation devices have shown significant improvements in outcome for patients after TKR [71]. Currently, compact and wireless EMG stimulation devices such as Myo-Ex (Biometrics Ltd., Newport, UK) can be used and have shown rehabilitation benefits in stroke patients [72].
To date, a number of protocol papers for advance rehabilitation technology RCTs have been published in the orthopaedic field [73–75]. As these studies mature, they will provide the high-level evidence needed, when deciding which of these technologies will be useful in the clinical setting.
Conclusion
This narrative literature review describes the variety of advanced rehabilitation technologies that are currently used in orthopaedics. It outlines the evidence for the extent to which these technologies can support and complement traditional therapy.
Hospital-based technology, such as robotic devices, is widely used mainly in SCI, and it is expected that they will be utilised for other conditions in the future. The reliability of ETS for measuring kinematics of upper and lower limbs has been reported, but the challenge is to develop compact and user-friendly devices. Unlike hospital-based advanced rehabilitation technology, home-based technologies such as inertial sensor, application, and CAGC are relatively inexpensive and user-friendly, making them more accessible. A number of these modalities have been shown to be effective measurement tools in orthopaedics through accurate quantification of patient physical activities such as dynamic ROM and function. VC, a method of telerehabilitation, is acceptable to most patients, and it promotes the patient-therapist relationship and the patient’s knowledge and motivation for rehabilitation.
The use of advanced rehabilitation technology in orthopaedics shows a lot of promise, particularly to support and complement traditional rehabilitation services, and its use is gaining in popularity. These technologies are dependent on the device accuracy and reliability. There remains a paucity of high-level published evidence as to efficacy. Further research is needed to determine the usability, cost-effectiveness and efficacy of advanced rehabilitation technology in high-quality randomised cohorts of orthopaedic patients.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Yuichi Kuroda and Matthew Young contributed equally to this work.
References
- 1.Koller-Hodac A, Leonardo D, Walpen S, Felder D. Knee orthopaedic device how robotic technology can improve outcome in knee rehabilitation. IEEE Int Conf Rehabil Robot. 2011;2011:5975347. doi: 10.1109/ICORR.2011.5975347. [DOI] [PubMed] [Google Scholar]
- 2.Kairy D, Tousignant M, Leclerc N, Cote AM, Levasseur M, Researchers TT. The patient’s perspective of in-home telerehabilitation physiotherapy services following total knee arthroplasty. Int J Environ Res Public Health. 2013;10(9):3998–4011. doi: 10.3390/ijerph10093998. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Mills PM, Morrison S, Lloyd DG, Barrett RS. Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotion. J Biomech. 2007;40(7):1504–1511. doi: 10.1016/j.jbiomech.2006.06.017. [DOI] [PubMed] [Google Scholar]
- 4.Cheung EYY, Ng TKW, Yu KKK, Kwan RLC, Cheing GLY. Robot-assisted training for people with spinal cord injury: a meta-analysis. Arch Phys Med Rehabil. 2017;98(11):2320–2331 e2312. doi: 10.1016/j.apmr.2017.05.015. [DOI] [PubMed] [Google Scholar]
- 5.Room J, Hannink E, Dawes H, Barker K. What interventions are used to improve exercise adherence in older people and what behavioural techniques are they based on? A systematic review. BMJ Open. 2017;7(12):e019221. doi: 10.1136/bmjopen-2017-019221. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Guzmán CH, Blanco A, Brizuela JA, Gómez FA. Robust control of a hip–joint rehabilitation robot. Biomed Signal Process Control. 2017;35:100–109. doi: 10.1016/j.bspc.2017.03.002. [DOI] [Google Scholar]
- 7.Bassett SF. The assessment of patient adherence to physiotherapy rehabilitation. N Z J Physiother. 2003;31(2):60–66. [Google Scholar]
- 8.Tousignant M, Boissy P, Moffet H, Corriveau H, Cabana F, Marquis F, Simard J. Patients’ satisfaction of healthcare services and perception with in-home telerehabilitation and physiotherapists’ satisfaction toward technology for post-knee arthroplasty: an embedded study in a randomized trial. Telemed J E Health. 2011;17(5):376–382. doi: 10.1089/tmj.2010.0198. [DOI] [PubMed] [Google Scholar]
- 9.Fung V, Ho A, Shaffer J, Chung E, Gomez M. Use of Nintendo Wii Fit in the rehabilitation of outpatients following total knee replacement: a preliminary randomised controlled trial. Physiotherapy. 2012;98(3):183–188. doi: 10.1016/j.physio.2012.04.001. [DOI] [PubMed] [Google Scholar]
- 10.Eriksson L, Lindstrom B, Ekenberg L. Patients’ experiences of telerehabilitation at home after shoulder joint replacement. J Telemed Telecare. 2011;17(1):25–30. doi: 10.1258/jtt.2010.100317. [DOI] [PubMed] [Google Scholar]
- 11.O’Driscoll SW, Giori NJ. Continuous passive motion (CPM): theory and principles of clinical application. J Rehabil Res Dev. 2000;37(2):179–188. [PubMed] [Google Scholar]
- 12.Lachiewicz PF. The role of continuous passive motion after total knee arthroplasty. Clin Orthop Relat Res. 2000;380:144–150. doi: 10.1097/00003086-200011000-00019. [DOI] [PubMed] [Google Scholar]
- 13.Naylor JM, Ko V, Rougellis S, Green N, Mittal R, Heard R, Yeo AE, Barnett A, Hackett D, Saliba C, Smith N, Mackey M, Harmer A, Harris IA, Adie S, McEvoy L. Is discharge knee range of motion a useful and relevant clinical indicator after total knee replacement? Part 2. J Eval Clin Pract. 2012;18(3):652–658. doi: 10.1111/j.1365-2753.2011.01656.x. [DOI] [PubMed] [Google Scholar]
- 14.Liao CD, Tsauo JY, Huang SW, Chen HC, Chiu YS, Liou TH. Preoperative range of motion and applications of continuous passive motion predict outcomes after knee arthroplasty in patients with arthritis. Knee Surg Sports Traumatol Arthrosc. 2019;27(4):1259–1269. doi: 10.1007/s00167-018-5257-z. [DOI] [PubMed] [Google Scholar]
- 15.Salter RB. The biologic concept of continuous passive motion of synovial joints. The first 18 years of basic research and its clinical application. Clin Orthop Relat Res. 1989;242:12–25. [PubMed] [Google Scholar]
- 16.Jaspers T, Taeymans J, Hirschmüller A, Baur H, Hilfiker R, Rogan S. Continuous passive motion does improve range of motion, pain and swelling after ACL reconstruction: a systematic review and meta-analysis. Z Orthop Unfall. 2019;157(03):279–291. doi: 10.1055/a-0710-5127. [DOI] [PubMed] [Google Scholar]
- 17.Bram JT, Gambone AJ, DeFrancesco CJ, Striano BM, Ganley TJ. Use of continuous passive motion reduces rates of arthrofibrosis after anterior cruciate ligament reconstruction in a pediatric population. Orthopedics. 2018;42(1):e81–e85. doi: 10.3928/01477447-20181120-04. [DOI] [PubMed] [Google Scholar]
- 18.Viveen J, Doornberg JN, Kodde IF, Goossens P, Koenraadt KL, Eygendaal D. Continuous passive motion and physical therapy (CPM) versus physical therapy (PT) versus delayed physical therapy (DPT) after surgical release for elbow contractures; a study protocol for a prospective randomized controlled trial. BMC Musculoskelet Disord. 2017;18(1):484. doi: 10.1186/s12891-017-1854-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Kizil R, Dilek B, Şahin E, Engin O, Soylu AC, Akalin E, Alper S. Is continuous passive motion effective in patients with lymphedema? A randomized controlled trial. Lymphat Res Biol. 2018;16(3):263–269. doi: 10.1089/lrb.2017.0018. [DOI] [PubMed] [Google Scholar]
- 20.Mavroidis C, Nikitczuk J, Weinberg B, Arango R, Danaher G, Jensen K, Leahey M, Pavone R, Pelletier P. International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. 2005. Provo A Smart portable rehabilitation devices; pp. 501–510. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Nakagawa TH, Moriya ET, Maciel CD, Serrao FV. Test-retest reliability of three-dimensional kinematics using an electromagnetic tracking system during single-leg squat and stepping maneuver. Gait Posture. 2014;39(1):141–146. doi: 10.1016/j.gaitpost.2013.06.011. [DOI] [PubMed] [Google Scholar]
- 22.Seitz AL, Reinold M, Schneider RA, Gill TJ, Thigpen CA. No effect of scapular position on 3-dimensional scapular motion in the throwing shoulder of healthy professional pitchers. J Sport Rehabil. 2012;21(2):186–193. doi: 10.1123/jsr.21.2.186. [DOI] [PubMed] [Google Scholar]
- 23.Hoshino Y, Miyaji N, Nishida K, Nishizawa Y, Araki D, Kanzaki N, Kakutani K, Matsushita T, Kuroda R. The concomitant lateral meniscus injury increased the pivot shift in the anterior cruciate ligament-injured knee. Knee Surg Sports Traumatol Arthrosc. 2019;27(2):646–651. doi: 10.1007/s00167-018-5209-7. [DOI] [PubMed] [Google Scholar]
- 24.Kuroda R, Hoshino Y. Electromagnetic tracking of the pivot-shift. Curr Rev Musculoskelet Med. 2016;9(2):164–169. doi: 10.1007/s12178-016-9335-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Nas K, Yazmalar L, Sah V, Aydin A, Ones K. Rehabilitation of spinal cord injuries. World J Orthop. 2015;6(1):8–16. doi: 10.5312/wjo.v6.i1.8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Holanda LJ, Silva PMM, Amorim TC, Lacerda MO, Simao CR, Morya E. Robotic assisted gait as a tool for rehabilitation of individuals with spinal cord injury: a systematic review. J Neuroeng Rehabil. 2017;14(1):126. doi: 10.1186/s12984-017-0338-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Schwartz I, Sajina A, Neeb M, Fisher I, Katz-Luerer M, Meiner Z. Locomotor training using a robotic device in patients with subacute spinal cord injury. Spinal Cord. 2011;49(10):1062–1067. doi: 10.1038/sc.2011.59. [DOI] [PubMed] [Google Scholar]
- 28.Chisholm AE, Malik RN, Blouin JS, Borisoff J, Forwell S, Lam T. Feasibility of sensory tongue stimulation combined with task-specific therapy in people with spinal cord injury: a case study. J Neuroeng Rehabil. 2014;11:96. doi: 10.1186/1743-0003-11-96. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Donati AR, Shokur S, Morya E, Campos DS, Moioli RC, Gitti CM, Augusto PB, Tripodi S, Pires CG, Pereira GA, Brasil FL, Gallo S, Lin AA, Takigami AK, Aratanha MA, Joshi S, Bleuler H, Cheng G, Rudolph A, Nicolelis MA. Long-Term training with a brain-machine interface-based gait protocol induces partial neurological recovery in paraplegic patients. Sci Rep. 2016;6:30383. doi: 10.1038/srep30383. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Schwartz I, Meiner Z. Robotic-assisted gait training in neurological patients: who may benefit. Ann Biomed Eng. 2015;43(5):1260–1269. doi: 10.1007/s10439-015-1283-x. [DOI] [PubMed] [Google Scholar]
- 31.Bolliger M, Trepp A, Zorner B, Dietz V. Modulation of spinal reflex by assisted locomotion in humans with chronic complete spinal cord injury. Clin Neurophysiol. 2010;121(12):2152–2158. doi: 10.1016/j.clinph.2010.05.018. [DOI] [PubMed] [Google Scholar]
- 32.Kawashima N, Taguchi D, Nakazawa K, Akai M. Effect of lesion level on the orthotic gait performance in individuals with complete paraplegia. Spinal Cord. 2006;44(8):487–494. doi: 10.1038/sj.sc.3101916. [DOI] [PubMed] [Google Scholar]
- 33.Wall A, Borg J, Palmcrantz S. Clinical application of the hybrid assistive limb (HAL) for gait training-a systematic review. Front Syst Neurosci. 2015;9:48. doi: 10.3389/fnsys.2015.00048. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Zariffa J, Kapadia N, Kramer JL, Taylor P, Alizadeh-Meghrazi M, Zivanovic V, Willms R, Townson A, Curt A, Popovic MR, Steeves JD. Effect of a robotic rehabilitation device on upper limb function in a sub-acute cervical spinal cord injury population. IEEE Int Conf Rehabil Robot. 2011;2011:5975400. doi: 10.1109/ICORR.2011.5975400. [DOI] [PubMed] [Google Scholar]
- 35.Singh H, Unger J, Zariffa J, Pakosh M, Jaglal S, Craven BC, Musselman KE. Robot-assisted upper extremity rehabilitation for cervical spinal cord injuries: a systematic scoping review. Disabil Rehabil Assist Technol. 2018;13(7):704–715. doi: 10.1080/17483107.2018.1425747. [DOI] [PubMed] [Google Scholar]
- 36.Sicuri C, Porcellini G, Merolla G. Robotics in shoulder rehabilitation. Muscles Ligaments Tendons J. 2014;4(2):207–213. doi: 10.32098/mltj.02.2014.21. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Bradley D, Acosta-Marquez C, Hawley M, Brownsell S, Enderby P, Mawson S. NeXOS – the design, development and evaluation of a rehabilitation system for the lower limbs. Mechatronics. 2009;19(2):247–257. doi: 10.1016/j.mechatronics.2008.07.006. [DOI] [Google Scholar]
- 38.Ferris DP, Czerniecki JM, Hannaford B. An ankle-foot orthosis powered by artificial pneumatic muscles. J Appl Biomech. 2005;21(2):189–197. doi: 10.1123/jab.21.2.189. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Boonstra MC, van der Slikke RM, Keijsers NL, van Lummel RC, de Waal Malefijt MC, Verdonschot N. The accuracy of measuring the kinematics of rising from a chair with accelerometers and gyroscopes. J Biomech. 2006;39(2):354–358. doi: 10.1016/j.jbiomech.2004.11.021. [DOI] [PubMed] [Google Scholar]
- 40.Saber-Sheikh K, Bryant EC, Glazzard C, Hamel A, Lee RY. Feasibility of using inertial sensors to assess human movement. Man Ther. 2010;15(1):122–125. doi: 10.1016/j.math.2009.05.009. [DOI] [PubMed] [Google Scholar]
- 41.Kumar Y, Yen SC, Tay A, Lee W, Gao F, Zhao Z, Li J, Hon B, Tian-Ma Xu T, Cheong A, Koh K, Ng YS, Chew E, Koh G. Wireless wearable range-of-motion sensor system for upper and lower extremity joints: a validation study. Healthc Technol Lett. 2015;2(1):12–17. doi: 10.1049/htl.2014.0100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Tulipani L, Boocock MG, Lomond KV, El-Gohary M, Reid DA, Henry SM. Validation of an inertial sensor system for physical therapists to quantify Movement coordination during functional tasks. J Appl Biomech. 2018;34(1):23–30. doi: 10.1123/jab.2016-0139. [DOI] [PubMed] [Google Scholar]
- 43.Matera G, Boonyasirikool C, Saggini R, Pozzi A, Pegoli L. The new smartphone application for wrist rehabilitation. J Hand Surg Asian Pac. 2016;21(1):2–7. doi: 10.1142/S2424835516400014. [DOI] [PubMed] [Google Scholar]
- 44.Quek J, Brauer SG, Treleaven J, Pua YH, Mentiplay B, Clark RA. Validity and intra-rater reliability of an android phone application to measure cervical range-of-motion. J Neuroeng Rehabil. 2014;11:65. doi: 10.1186/1743-0003-11-65. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Kolber MJ, Pizzini M, Robinson A, Yanez D, Hanney WJ. The reliability and concurrent validity of measurements used to quantify lumbar spine mobility: an analysis of an iphone(R) application and gravity based inclinometry. Int J Sports Phys Ther. 2013;8(2):129–137. [PMC free article] [PubMed] [Google Scholar]
- 46.Mitchell K, Gutierrez SB, Sutton S, Morton S, Morgenthaler A. Reliability and validity of goniometric iPhone applications for the assessment of active shoulder external rotation. Physiother Theory Pract. 2014;30(7):521–525. doi: 10.3109/09593985.2014.900593. [DOI] [PubMed] [Google Scholar]
- 47.Ferriero G, Sartorio F, Foti C, Primavera D, Brigatti E, Vercelli S. Reliability of a new application for smartphones (DrGoniometer) for elbow angle measurement. PM R. 2011;3(12):1153–1154. doi: 10.1016/j.pmrj.2011.05.014. [DOI] [PubMed] [Google Scholar]
- 48.Jenny JY. Measurement of the knee flexion angle with a Smartphone-application is precise and accurate. J Arthroplast. 2013;28(5):784–787. doi: 10.1016/j.arth.2012.11.013. [DOI] [PubMed] [Google Scholar]
- 49.Vohralik SL, Bowen AR, Burns J, Hiller CE, Nightingale EJ. Reliability and validity of a smartphone app to measure joint range. Am J Phys Med Rehabil. 2015;94(4):325–330. doi: 10.1097/PHM.0000000000000221. [DOI] [PubMed] [Google Scholar]
- 50.Stove MP, Palsson TS, Hirata RP. Smartphone-based accelerometry is a valid tool for measuring dynamic changes in knee extension range of motion. Knee. 2018;25(1):66–72. doi: 10.1016/j.knee.2017.11.001. [DOI] [PubMed] [Google Scholar]
- 51.Hoshino Y, Araujo P, Irrgang JJ, Fu FH, Musahl V. An image analysis method to quantify the lateral pivot shift test. Knee Surg Sports Traumatol Arthrosc. 2012;20(4):703–707. doi: 10.1007/s00167-011-1845-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Hoshino Y, Araujo P, Ahlden M, Samuelsson K, Muller B, Hofbauer M, Wolf MR, Irrgang JJ, Fu FH, Musahl V. Quantitative evaluation of the pivot shift by image analysis using the iPad. Knee Surg Sports Traumatol Arthrosc. 2013;21(4):975–980. doi: 10.1007/s00167-013-2396-0. [DOI] [PubMed] [Google Scholar]
- 53.Rathleff MS, Thorborg K, Rode LA, McGirr KA, Sorensen AS, Bogild A, Bandholm T. Adherence to commonly prescribed, home-based strength training exercises for the lower extremity can be objectively monitored using the bandcizer. J Strength Cond Res. 2015;29(3):627–636. doi: 10.1519/JSC.0000000000000675. [DOI] [PubMed] [Google Scholar]
- 54.McGirr K, Harring SI, Kennedy TS, Pedersen MF, Hirata RP, Thorborg K, Bandholm T, Rathleff MS. An elastic exercise band mounted with a bandcizer can differentiate between commonly prescribed home exercises for the shoulder. Int J Sports Phys Ther. 2015;10(3):332–340. [PMC free article] [PubMed] [Google Scholar]
- 55.Riel H, Matthews M, Vicenzino B, Bandholm T, Thorborg K, Rathleff MS. Feedback leads to better exercise quality in adolescents with patellofemoral pain. Med Sci Sports Exerc. 2018;50(1):28–35. doi: 10.1249/MSS.0000000000001412. [DOI] [PubMed] [Google Scholar]
- 56.Rathleff MS, Bandholm T, Ahrendt P, Olesen JL, Thorborg K. Novel stretch-sensor technology allows quantification of adherence and quality of home-exercises: a validation study. Br J Sports Med. 2014;48(8):724–728. doi: 10.1136/bjsports-2012-091859. [DOI] [PubMed] [Google Scholar]
- 57.Harrison R, Macfarlane A, Murray E, Wallace P. Patients’ perceptions of joint teleconsultations: a qualitative evaluation. Health Expect. 2006;9(1):81–90. doi: 10.1111/j.1369-7625.2006.00368.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Gilbert AW, Jaggi A, May CR. What is the acceptability of real time 1:1 videoconferencing between clinicians and patients for a follow-up consultation for multi-directional shoulder instability. Should Elb. 2019;11(1):53–59. doi: 10.1177/1758573218796815. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Ruff J, Wang TL, Quatman-Yates CC, Phieffer LS, Quatman CE. Commercially available gaming systems as clinical assessment tools to improve value in the orthopaedic setting: a systematic review. Injury. 2015;46(2):178–183. doi: 10.1016/j.injury.2014.08.047. [DOI] [PubMed] [Google Scholar]
- 60.Meldrum D, Glennon A, Herdman S, Murray D, McConn-Walsh R. Virtual reality rehabilitation of balance: assessment of the usability of the Nintendo Wii((R)) Fit Plus. Disabil Rehabil Assist Technol. 2012;7(3):205–210. doi: 10.3109/17483107.2011.616922. [DOI] [PubMed] [Google Scholar]
- 61.Clark RA, McGough R, Paterson K. Reliability of an inexpensive and portable dynamic weight bearing asymmetry assessment system incorporating dual Nintendo Wii Balance Boards. Gait Posture. 2011;34(2):288–291. doi: 10.1016/j.gaitpost.2011.04.010. [DOI] [PubMed] [Google Scholar]
- 62.Wochatz M, Tilgner N, Mueller S, Rabe S, Eichler S, John M, Voller H, Mayer F. Reliability and validity of the Kinect V2 for the assessment of lower extremity rehabilitation exercises. Gait Posture. 2019;70:330–335. doi: 10.1016/j.gaitpost.2019.03.020. [DOI] [PubMed] [Google Scholar]
- 63.Dutta T. Evaluation of the Kinect sensor for 3-D kinematic measurement in the workplace. Appl Ergon. 2012;43(4):645–649. doi: 10.1016/j.apergo.2011.09.011. [DOI] [PubMed] [Google Scholar]
- 64.Clark RA, Pua YH, Bryant AL, Hunt MA. Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining. Gait Posture. 2013;38(4):1064–1066. doi: 10.1016/j.gaitpost.2013.03.029. [DOI] [PubMed] [Google Scholar]
- 65.Obdrzalek S, Kurillo G, Ofli F, Bajcsy R, Seto E, Jimison H, Pavel M. Accuracy and robustness of Kinect pose estimation in the context of coaching of elderly population. Conf Proc IEEE Eng Med Biol Soc. 2012;2012:1188–1193. doi: 10.1109/EMBC.2012.6346149. [DOI] [PubMed] [Google Scholar]
- 66.Da Gama A, Fallavollita P, Teichrieb V, Navab N. Motor rehabilitation using kinect: a systematic review. Games Health J. 2015;4(2):123–135. doi: 10.1089/g4h.2014.0047. [DOI] [PubMed] [Google Scholar]
- 67.Yamada M, Aoyama T, Nakamura M, Tanaka B, Nagai K, Tatematsu N, Uemura K, Nakamura T, Tsuboyama T, Ichihashi N. The reliability and preliminary validity of game-based fall risk assessment in community-dwelling older adults. Geriatr Nurs. 2011;32(3):188–194. doi: 10.1016/j.gerinurse.2011.02.002. [DOI] [PubMed] [Google Scholar]
- 68.Baltaci G, Harput G, Haksever B, Ulusoy B, Ozer H. Comparison between Nintendo Wii Fit and conventional rehabilitation on functional performance outcomes after hamstring anterior cruciate ligament reconstruction: prospective, randomized, controlled, double-blind clinical trial. Knee Surg Sports Traumatol Arthrosc. 2013;21(4):880–887. doi: 10.1007/s00167-012-2034-2. [DOI] [PubMed] [Google Scholar]
- 69.Pagnacco G, Oggero E, Wright C. Biomedical instruments versus toys: a preliminary comparison of force platforms and the nintendo wii balance board-biomed 2011. Biomed Sci Instrum. 2011;47:12–17. [PubMed] [Google Scholar]
- 70.Gumaa M, Youssef AR (2019) Is virtual reality effective in orthopedic rehabilitation? A systematic review and meta-analysis. Phys Ther. 10.1093/ptj/pzz093 [DOI] [PubMed]
- 71.Pfeufer D, Gililland J, Bocker W, Kammerlander C, Anderson M, Krahenbuhl N, Pelt C. Training with biofeedback devices improves clinical outcome compared to usual care in patients with unilateral TKA: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2019;27(5):1611–1620. doi: 10.1007/s00167-018-5217-7. [DOI] [PubMed] [Google Scholar]
- 72.Park YK, Kim JH. Effects of kinetic chain exercise using EMG-biofeedback on balance and lower extremity muscle activation in stroke patients. J Phys Ther Sci. 2017;29(8):1390–1393. doi: 10.1589/jpts.29.1390. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 73.Nerz C, Schwickert L, Becker C, Studier-Fischer S, Mussig JA, Augat P. Effectiveness of robot-assisted training added to conventional rehabilitation in patients with humeral fracture early after surgical treatment: protocol of a randomised, controlled, multicentre trial. Trials. 2017;18(1):589. doi: 10.1186/s13063-017-2274-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 74.Zadro JR, Shirley D, Simic M, Mousavi SJ, Ceprnja D, Maka K, Ferreira P. Video-game based exercises for older people with chronic low back pain: a protocol for a feasibility randomised controlled trial (the GAMEBACK trial) Physiotherapy. 2017;103(2):146–153. doi: 10.1016/j.physio.2016.05.004. [DOI] [PubMed] [Google Scholar]
- 75.Negus JJ, Cawthorne DP, Chen JS, Scholes CJ, Parker DA, March LM. Patient outcomes using Wii-enhanced rehabilitation after total knee replacement - the TKR-POWER study. Contemp Clin Trials. 2015;40:47–53. doi: 10.1016/j.cct.2014.11.007. [DOI] [PubMed] [Google Scholar]