Skip to main content
. Author manuscript; available in PMC: 2022 Apr 1.
Published in final edited form as: Proc IEEE Int Symp Biomed Imaging. 2021 May 25;2021:10.1109/isbi48211.2021.9433926. doi: 10.1109/isbi48211.2021.9433926

Table 1.

Comparison of Dice Score and ASD on different regularization methods.

Metric Organ Moving SyN w/o Reg L2 L1 BE Ours
Dice (%) Liver 76.23 ±4.48 79.42±4.25 45.37±7.69 82.97 ±3.73 81.03 ±3.55 83.05±3.28 86.67±3.07
Spleen 77.94±3.49 80.33±3.37 36.24±6.23 82.28 ±3.02 81.84±3.14 83.46±2.95 85.13±2.99
Kidney 80.18±3.24 82.68 ±2.96 42.86±7.42 85.01±3.18 84.59±3.07 84.67±3.52 85.38±3.11
ASD (mm) Liver 4.98 ±0.85 4.83 ±0.73 8.42±2.18 3.94±0.64 3.82±0.69 3.52±0.82 2.69±0.56
Spleen 2.02 ±0.68 1.62±0.62 7.04±1.97 1.45±0.59 1.51±0.54 1.48 ±0.61 1.31±0.57
Kidney 1.95±0.43 1.91 ±0.47 6.83 ±2.09 1.73±0.38 1.78 ±0.33 1.69 ±0.37 1.45±0.39