Skip to main content
. 2021 Aug 3;21(15):5247. doi: 10.3390/s21155247

Table 2.

Descriptive statistical analysis after the OptoGait sensor gait analysis between the control and case groups.

Sample
n = 147
Group
Case
n = 75
Control
n = 72
p-Value
Right foot stride length, cm 60.50 (3.00) 60.70 (2.80) 60.40 (4.15) p = 0.901
Left foot stride length, cm 60.10 (4.40) 60.30 (6.50) 59.90 (2.70) p = 0.438
Ground contact time:
Right foot sec 0.54 (0.03) 0.54 (0.03) 0.54 (0.09) p = 0.332
Step % 70.50 (6.70) 65.00 (9.30) 71.10 (1.40) p = 0.001
Left foot sec 0.54 (0.03) 0.54 (0.06) 0.55 (0.06) p = 0.101
Step % 70.10 (7.60) 66.00 (10.47) 70.80 (1.00) p = 0.001
Difference stride% 0.10 (3.30) −0.70 (3.40) −0.93 (3.00) p = 0.001
Difference contact% −0.70 (1.50) −0.70 (2.10) −0.60 (1.10) p = 0.050
Gait cycle sec 1.10 (0.05) 1.09 (0.06) 1.11 (0.06) p = 0.867
Gait cadence spm 107.90 (9.40) 107.03 (8.70) 110.90 (8.80) p = 0.013
Total Stride length cm
Speed, Km/h
119.90 (6.20)
4.33 (0.74)
122.50 (8.45)
4.21 (0.82)
119.50 (3.30)
4.38 (0.92)
p = 0.036
p = 0.043

Values are presented as median (interquartile ranges). The Mann–Whitney U-Test was used. Significance set at p < 0.05.