Background

Histological images show strong variance (e.g. illumination, color, staining quality) due to differences in image acquisition, tissue processing, staining, etc. This can impede downstream image analysis such as staining intensity evaluation or classification. Methods to reduce these variances are called image normalization techniques.

Methods

In this paper, we investigate the potential of CycleGAN (cycle consistent Generative Adversarial Network) for color normalization in hematoxylin-eosin stained histological images using daily clinical data with consideration of the variability of internal staining protocol variations. The network consists of a generator network GB that learns to map an image X from a source domain A to a target domain B, i.e. GB:XAXB. In addition, a discriminator network DB is trained to distinguish whether an image from domain B is real or generated. The same process is applied to another generator-discriminator pair (GA,DA), for the inverse mapping GA:XBXA. Cycle consistency ensures that a generated image is close to its original when being mapped backwards (GA(GB(XA))≈XA and vice versa). We validate the CycleGAN approach on a breast cancer challenge and a follicular thyroid carcinoma data set for various stain variations. We evaluate the quality of the generated images compared to the original images using similarity measures. In addition, we apply stain normalization on pathological lymph node data from our institute and test the gain from normalization on a ResNet classifier pre-trained on the Camelyon16 data set.

Results

Qualitative results of the images generated by our network are compared to original color distributions. Our evaluation indicates that by mapping images to a target domain, the similarity training images from that domain improves up to 96%. We also achieve a high cycle consistency for the generator networks by obtaining similarity indices greater than 0.9. When applying the CycleGAN normalization to HE-stain images from our institute the kappa-value of the ResNet-model that is only trained on Camelyon16 data is increased more than 50%.

Conclusions

CycleGANs have proven to efficiently normalize HE-stained images. The approach compensates for deviations resulting from image acquisition (e.g. different scanning devices) as well as from tissue staining (e.g. different staining protocols), and thus overcomes the staining variations in images from various institutions.The code is publicly available at https://github.com/m4ln/stainTransfer_CycleGAN_pytorch. The data set supporting the solutions is available at 10.11588/data/8LKEZF.

Keywords: Histology stain normalization, HE-stain, Digital pathology, Generative adversarial networks, Unpaired image-to-image translation, Style transfer, Deep learning

Background

In both histology and surgical pathology, the inherent individual appearance of the considered object on the one hand or the different staining protocols on the other hand must be compensated in addition to factors that influence the image acquisition (e.g scanning devices). This demand applies to hematoxylin-eosin (HE) staining being the standard method in pathology but also to all other histochemical and immunohistochemical staining. Regarding HE-staining, solutions and protocols are standardized at first glance. However, even within a single institution, protocols may vary slightly and may not be coordinated with other institutes. Especially when training deep neural networks, for example for image classification, there is a need for stain normalization of images so that models are transferable to other data sets.

The term color normalization is an umbrella term for image processing techniques compensating for effects such as variable illumination, camera setting, etc. This evident request drives an active research. Conventional image processing such as color deconvolution or look-up tables with the need for selecting a reference template slide for normalization are widespread [16]. A particular but quite similar issue is stain quantification [7, 8]. Recent publications investigated in the use of deep learning approaches with Generative Adversarial Networks (GANs) and showed the benefits compared to the conventional methods [9, 10]. It was also shown how normalizing images using GANs can highly improve results of image classification [11] or segmentation [12]. Mahapatra et al. [13] integrate self-supervised semantic information such as geometric and structural patterns at different layers to improve stain normalization with CycleGANs.

In this work, we investigate the potential and limitation of a machine learning-based approach for normalization with a cycle consistent Generative Adversarial Network (CycleGAN) which learns the mapping from one HE-stain variant to an other. The approach we follow was proposed by Zhu et al. [14]. An image-to-image mapping is learned between two different HE-stained data sets to generate fake images in each image domain. We apply the technique to two independent data sets: the Mitosis-Atypia-14 challenge which provides two image sets of breast cancer tissue scanned with two different devices, and our HE-Staining Variation (HEV) data set, showing follicular thyroid carcinoma slices stained with different protocols. We evaluate the results using the Fréchet Inception Distance (FID) and the Structural Similarity Index Measure (SSIM). In addition, we apply our method to a tumor classification task of lymph node samples, in which we apply stain normalization on pathological lymph node data from our institute and test the gain from normalization on a ResNet classifier pre-trained on the Camelyon16 data set. We show that normalization can increase the confidence of the classifier not only prior to the training, but also when the test data is normalized on the training set and applied to the model after training. In addition to that, we demonstrate the potential of using this normalization for recoloring images with stains that are not present in the original data; and at the same time we achieve a higher accuracy in our classification task.

We provide both, our implementation at https://github.com/m4ln/stainTransfer_CycleGAN_pytorch, and our data set for normalization and classification at 10.11588/data/8LKEZF.

Methods

CycleGAN formulation

The CycleGAN from Zhu et al. [14] consists of two generator and discriminator pairs each of which learns the mapping from one image domain to the other. Given the image domains A and B with training images XA and XB, the generator GB learns the mapping from A to B such that GB:XAXB, while the generator GA learns the mapping in reverse direction, i.e. GA:XBXA. A discriminator D is a binary classifier. It decides whether a sample is real (1), i.e. given from the training data set, or fake (0), i.e. produced by the generator. More precisely, discriminator DB learns to distinguish between real images XBreal and generated ones XBfake, while in the same way, DA is trained to discriminate between XAreal and XAfake.

For training, the objective function to be optimized is modeled by two loss functions: the adversarial loss adv [15] and the cycle consistency loss cyc [14].

Adversarial loss

Introduced by Goodfellow et al. [15] the adversarial loss refers to the two-player game between the generator and the discriminator networks. More precisely, for the mapping GB:XAXB, the discriminator DB is trained to classify XBreal and XBfake correctly, while the generator seeks XBfake being classified as real by the discriminator. In this way, both, the generator and the discriminator try to fool the other. Zhu et al. [14] use the least-squares loss as objective since it ensures stability during training and generates higher quality results. Thus, the adversarial loss function is expressed as follows [14]:

minGBmaxDBBadv=𝔼XBrealDBXBreal2+𝔼XArealDBGBXAreal12,

with 𝔼 being the expected value over all instances of XAreal and XBreal. In the same way, we can formulate the adversarial loss for the inverse mapping function GA:XBXA, i.e.

minGAmaxDAAadv=𝔼XArealDAXAreal2+𝔼XBrealDAGAXBreal12,

Thus, the total adversarial loss adv is obtained by the sum of both terms Aadv and Badv.

Cycle consistency loss

Zhu et al. [14] presented this loss function to enforce that both mapping functions GA and GB learned by the generators are inverse functions. In other words, if an image is mapped from one domain to the other domain the backward mapping should bring the image back to its original state. Thus, it must satisfy the cycle XArealGB(XAreal)GA(GB(XAreal))=XArecXAreal and in the same way for XBrealGA(XBreal)GB(GA(XBreal))=XBrecXBreal for the backward mapping. Therefore, the total cycle consistency is given by:

cyc=𝔼XArealGAGBXArealXAreal1Acyc+𝔼XBrealGBGAXBrealXBreal1Bcyc,

where ∥·∥1 denotes the 1-Norm.

Hence, the total loss function is

argminGB,GAargmaxDB,DA=adv+λcyc,

with λ being a regularization factor to control the relative importance of both, adversarial and cycle consistency losses.

Figure 1 illustrates the CycleGAN structure for mapping an image from domain A to domain B by GB:XArealXBfake and backwards by GA:XBfakeXArec. The discriminator DB tries to identify if an image is generated XBfake or real XBreal. During training, the network is optimized by computing the adversarial loss adv and the cycle consistency loss cyc. The same process is done for the reverse direction when a real sample image XBreal is mapped from domain B to domain A, i.e XBrealGAXAfakeGBXBrec.

Fig. 1.

Fig. 1

Illustration of the applied CycleGAN architecture for mapping images from domain A to domain B. A real sample image XAreal is mapped to domain B by the generator GB:XArealXBfake and then back to domain A by the generator GA:XBfakeXArec. The discriminator DB differentiates between the generated image XBfake and a real sample image XBreal. The same process is done for the reverse direction when mapping a real sample image XBreal from domain B to domain A and backwards, i.e XBGAXAfakeGBXBrec. During training, the loss is computed by the adversarial loss adv and the cycle consistency loss cyc

Data sets

Two data sets are used to asses the quality of stain normalization using CycleGAN: (a) The Mitos-Atypia-14 challenge data set in which the HE-stain in images appears different in color and resolution due to different scanning devices. (b) Our clinical HE-Staining Variation (HEV) data set, which contains images of serial sections that were subjected to different staining protocols. In addition, we apply our CycleGAN normalization method in a tumor lymph node classification task trained on the Camelyon16 data set [16] and tested on the TumorLymphnode data set collected at our institute.

Mitos-Atypia-14

This is a publicly available challenge data set containing breast-cancer images [17]. The tissue was HE-stained and scanned by two different whole-slide image (WSI) scanners: the Aperio ScanScope XT and the Hamamatsu Nanozoomer 2.0-HT. Both devices scan images with different resolutions, the Aperio 1539×1376 pixels and the Hamamatsu 1663×1485 pixels at X20 and X40 magnification. From each scanned set, 7,936 tiles are selected for training and 15,000 tiles for testing. We resize the images to 1024×1024 pixels and extract image tiles of 256×256 pixels as input to our network.

HE-Staining variation

At the Institute of Pathology, Medical Faculty Mannheim, Heidelberg University we collected serial sections of a follicular thyroid carcinoma and stained them with the following HE-staining variants: standard protocol (of the Institute of Pathology, Mannheim) HE-stain (henceforth HE), intentionally stained too short (henceforth shortHE), intentionally stained too long (henceforth longHE), only stained with hematoxylin (henceforth onlyH), and only stained with Eosin (henceforth onlyE). Figure 2 shows thumbnails from each WSI. For each set, we extract tiles of 256×256 pixels. We collect 10,000 and 15,000 tiles for training and testing, respectively. The whole data set including our training patches is made publicly available [18].

Fig. 2.

Fig. 2

Exemplary miniature image of the WSI that forms the HEV data set. Serial tissue sections from a thyroid tissue with a follicular carcinoma with HE-staining. For every slide the staining protocol is intentionally modified: A) Standard protocol at the Institute of Pathology, Medical Faculty Mannheim, Heidelberg University (HE) B) Shortened staining time (shortHE) C) Prolonged staining time (longHE) D) Only hematoxylin-stain (onlyH) E) Only eosin-stain (onlyE)

Image classification

The effect of HE-staining normalization is applied on a tumor classification task using two sets of data: (1) The Camelyon16 data set [16] containing the classes normal lymph node (n=3,318) and carcinoma infiltration (n=3,591), (2) Slides with normal lymph nodes and carcinoma infiltration from an interval of 15a (hereinafter called TumorLymphnode or short TL data set) collected from the Institute of Pathology, Heidelberg University. These are segmented manually and then cropped into tiles (n=3605 with normal lymph node parts, n=3,600 with carcinoma infiltration).

Training details

CycleGAN

In the first setting, we train our model on the Mitos-Atypia-14 challenge to learn the mapping between the two image sets XA and XB obtained by the scanners Aperio and Hamamatsu, respectively. We then train four additional models on the HEV data set, with set A being the standard stained tissue (see Fig. 2A) and set B being one of the other stained tissues (see Fig. 2B-E). For each model we choose 10,000 images for training. An overview of the experiments on stain normalization are given in the Appendix.

For the classification task, we train a CycleGAN to normalize the Camelyon16 data set to the standard HE and hematoxylin staining of the HEV data set and to the TL data set. In the same way we train another model to normalize the TL data set to the Cameylon16 data set and to the HE and hematoxylin staining of the HEV data set. For each image set we choose 5,000 images for training.

For all models we use the same network architecture as described by Zhu et al. [14]. We train each network for 60 epochs in total where the initial learning-rate is set to 2e−4 and then decreases to zero after every 30 epochs. The regularization factor λ is set to 10 for all experiments. Adam optimizer is used (β1=0.5,β2=0.999) with a batch size of 1. We train and evaluate the models on an NVIDIA Quadro P6000 graphics card.

ResNet

A ResNet [19] - in its Pytorch-implementation - is trained on the original Camelyon16 data set and its normalized versions to the HEV and TL data sets (using CycleGAN), to classify images into the two classes normal lymph node and carcinoma infiltration. Each network is trained for 100 epochs in total with a learning-rate of 2e−4.

Evaluation metrics

To assess the quality of the images generated by the CycleGAN we use the Fréchet Inception Distance (FID), to compare the distribution of generated images with the distribution of real images. In addition, the successful training of both generators is assessed by computing the Structural Similarity Index Measure (SSIM) in various windows between a real image and its reconstruction through the generator. For the classification task, we calculate kappa-values from the confusion matrix.

FID

This metric consists of the Fréchet distance also known as Wasserstein-2 distance computed on the basis of feature vectors. Here, a feature vector is the 2048-sized output of a pre-trained inception v3 model applied on one image. For the whole set of input images we get a sample of feature vectors with m1 as its collective mean and C1 as its covariance while for the GAN output images we get m2,C2 respectively [20]. The Fréchet distance is then applied to calculate the minimum distance between the means and covariances [21]:

d2(m1,C1),(m2,C2)=||m1m2||2+TrC1+C22C1C2.

For identical image sets the FID is zero, whereas it increases with noise and disturbances. The python code for computing FID scores is used from [22].

SSIM

For a given original image x and the corresponding output of the GAN y the features luminance l(x,y), contrast c(x,y) and structure s(x,y) are compared on basis of the respective average, variance and covariance. The product of these components with the weighting factors α,β,γ yields the SSIM:

SSIM(x,y)=l(x,y)α·c(x,y)β·s(x,y)γ.

The SSIM metric is applied on image pairs showing the same image content. It ranges from 0 to 1 and equals one only for exact identical images. An SSIM close to zero hardly represents similar images [23]. We use the python code from [24] to compute SSIM scores.

Cohen’s kappa

The kappa-values are calculated from the confusion matrix using scikit-learn’s function cohen_kappa_score [25]. The kappa score ranges from -1 and 1. A value ≥ 0.8 is considered as almost perfect agreement while ≤ 0 means no agreement (i.e. random labels) [26].

Results

We show the visual and evaluation results of our CycleGAN experiments on the Mitos-Atypia-14 and HEV data sets. For generators GA and GB, image tiles from image domains A and B can be normalized in both directions such that XArealGBXBfakeGAXArec and XBrealGAXAfakeGBXBrec. In addition, we show the results of our experiments on the lymph node classification task with HE-stain normalization.

CycleGAN visual results

Mitos-Atypia-14

Example results of on the Mitos-Atypia-14 data set are shown in Fig. 3. Columns A-C refer to the image tiles scanned by the Aperio scanner (XAreal) being mapped by the generator GB to produce the corresponding image in the domain of the Hamamatsu scanner (XBfake) and the reconstruction from mapping the image back to its original domain (XArec). The same process is done in the reverse direction for image tiles scanned in domain B being mapped to domain A and backward (columns D-F). Each row 1-4 presents another example image.

Fig. 3.

Fig. 3

Results gallery from our experiments on the Mitos-Atypia-14 challenge data set. Columns A-C refer to the image tiles scanned by the Aperio scanner (XAreal) being mapped by the generator GB to produce the corresponding image in the domain of the Hamamatsu scanner (XBfake) and the reconstruction from mapping the image back to its source domain (XArec), i.e XArealGBXBfakeGAXArec. The same process is done in the reverse direction for image tiles scanned in domain B, i.e XBrealGAXAfakeGBXBrec (column D-F). Each row 1-4 presents another example tissue section

HE-Staining variation

Figure 4 presents several test results when mapping a standard stained HE-image XAreal to one of the four stains of domain XBfake. Each block A-D shows another example tissue section. The top row of each block represents an exemplary image tile of the stain to be mapped into (shortHE, longHE, onlyH, onlyE), while the bottom row depicts the input image (HE) and the corresponding output for each stain.

Fig. 4.

Fig. 4

Results gallery from our experiments on the HEV data set for the mapping GB:XArealXBfake. Here, the input image is from domain A of the standard stained tissue (HE) being mapped to domain B corresponding to the image-sets shortHE, longHE, onlyH, onlyE. Each block A-D shows another example tissue section. The top row of each block represents an exemplary image tile of the stain to be mapped into, while the bottom row depicts the input image and the corresponding output for each stain

CycleGAN evaluation

For all five experiments FID scores are shown in Fig. 5A. As reference, FID scores of all testing images from data sets A and B (blue) are computed. They range between 31.5 (MA14) to 203.68 (onlyE). Our experiments achieve on average FID scores for real vs. fake of 7.09 (A) and 6.93 (B), while for real vs. rec we obtain an average of 5.76 (A) and 5.58 (B). When mapping images from a source domain to a target domain, the FID scores compared to original images from the target domain improve up to 96% (blue vs. orange, red, green and purple). More precisely, for each experiment it is 76.85% (MA14), 91.93% (shortHE), 89.23% (longHE), 95.76% (onlyH), 95.57% (onlyE). A table with all FID is presented in the Appendix.

Fig. 5.

Fig. 5

Evaluation of our experiments using FID and SSIM scores. A) FID scores between real and generated (fake, rec) images. For identical images the FID is zero, whereas it increases with noise and disturbances. B) SSIM scores between real vs. rec images. The SSIM scale ranges from 0 to 1 and is close to zero for hardly similar images. A table with all FID and SSIM scores is presented in the Appendix

In addition, SSIM scores (see Fig. 5B) are computed between the real and their reconstructed images for each image domain A (blue) and B (orange). Each value refers to the average SSIM for all test images and the bars represent the corresponding standard deviation (SD). For each set A we obtain SSIM scores in the range of SSIM=0.94 (SD=0.02) (MA14) and SSIM=0.97 (SD=0.01) (onlyH), whereas for set B we obtain scores between SSIM=0.96 (SD=0.02) (MA14) and SSIM=0.98 (SD=0.01) (onlyH). A table with all SSIM scores is presented in the Appendix.

Stain normalization in image classification

In order to sow the impact of stain normalization on a downstream task such as image classification or segmentation, a ResNet [19] for the Camelyon16 data set, and its normalized versions, was trained. It should be noted that a standard color normalization to the mean and standard deviation as well as data augmentation with the albumentations package [27] is carried out in the standard training setting. The model learns to classify the images in lymph node parts with (hereinafter called tumor) and without (hereinafter called normal) carcinoma infiltration. Our three ResNets are tested on the Camelyon16 data set (n=830 images without and n=898 images with tumor) in original, normalized to the HEV data set and normalized to the TL data set as well as to the TL data set (n=902 images without and n=900 images with tumor) in original, normalized to the HEV data set and normalized to the Camelyon16 data set. As shown in Table 1 all ResNet models work best with images of the same HE-staining from the same training data set (Camelyon16 original, normalized to the HEV or TL data set). Furthermore, the models can best be applied to or transferred to the images from the TL data set, which in turn have the same HE-staining or stain normalization. However, with a best kappa-values of 0.55, this transfer from the Camelyon16 data set to the TumorLymphnode data set does not work very well. Also the ResNet-model trained on hematoxylin normalized images is able to classify other hematoxylin images correctly (kappa-value 0.77 for the Camelyon16 data set and 0.54 for the TL data set). The complete table of the results is shown in the Appendix.

Table 2.

Overview of our stain normalization experiments

Data set Experiment Name Set A Set B
Mistos-Atypia-14 MA14 Aperio scanner Hamamatsu scanner
HEV shortHE standard HE stained shortened staining time
longHE prolonged staining time
onlyH only stained with hematoxylin
onlyE only stained with eosin
Camelyon16 Cam_HE Camelyon16 standard HE stained
Cam_TL TumorLymphnode
TumorLymphnode TL_HE TumorLymphnode standard HE stained
TL_Cam Camelyon16

Table 1.

Kappa-values for the ResNet models that were trained on different versions of the Camelyon16 data set

model / data Cam_ori Cam_HE Cam_TL TL_ori TL_HE TL_Cam
ResNet_ori 0.85 0.00 0.12 0.00 0.00 0.54
ResNet_HE 0.02 0.79 0.28 0.13 0.55 0.01
ResNet_TL 0.36 0.10 0.79 0.55 0.08 0.24

The training images (from the Camelyon16 data set) are 1) original (Cam_ori), 2) normalized by the CycleGAN to the HEV data set (Cam_HE) or 3) the TL data set (Cam_TL), respectively. For each training sets, a ResNet model was trained: 1) ResNet_ori, 2) ResNet_HE and 3) ResNet_TL. All models were tested on images from the Camelyon16 data set (n=1728 images) and the TL data set (n=1802 images). There were again three versions of both test data sets: one original version (Cam_ori and TL_ori), one version normalized to the HEV data set (Cam_HE and TL_HE), and one version normalized to the Camelyon16 (TL_Cam) or the TL data set (Cam_TL). The best kappa value obtained for each test set (column-wise) on all models is shown in bold

Discussion

This paper underlines that CycleGANs for image normalization in the context of digital pathology [12] yield a clear clinical benefit. The trained CycleGAN models show compelling results, both visually (Figs. 3 and 4) and quantitatively (Fig. 5) by obtaining FID scores up to 96% better for images mapped to a target domain. The trained models are able to fully convert to the desired color scheme while preserving the structural contents of the original image due to the cycle consistency constraint leading to SSIM scores greater than 0.9 when mapping generated images back to their source domain.

Furthermore, we could confirm that this normalization approach can be beneficial for image classification tasks. Similar to the results of Shaban et al. [10] for the Camelyon16 data set, Yuan et al. [28] for a number of publicly available data sets or de Bel et al. [12] in the application of image segmentation. Compared to earlier approaches on public data sets, in our work we demonstrate how stain normalization improves the classification accuracy, when applied to multiple internal data on a pre-trained model. When normalizing HE-stain images from our institute to the Camelyon16 data set and testing a ResNet-model that is only trained on Camelyon16 data the kappa-value increased more than 50%. Furthermore, we were able to show in a first approach that such a normalization could also enable the use of different colored data sets for downstream tasks, e.g. by converting both data sets to a different staining. However, further work, e.g using more different staining methods, is certainly necessary here.

Some limitations of the used CycleGAN-model can also be seen when mapping images obtained by different scanning devices with varying resolutions. This can cause a loss in structural information despite the consistently good quality of the color normalization. With the HEV data set, the generated images look very realistic compared to the original images in a target domain without any decline in the image content (see Fig. 4).

The CycleGAN approach used here is able to successfully learn every mapping between two image stains and can instantly normalize any unseen image if it is within one of the trained stains. For each other staining, the network needs to be retrained from scratch. However, the network is able to learn even from a small amount of images (1,000-10,000 per set) which can be obtained from a single WSI. In addition, the images do not have to be labeled or paired to learn the mapping between two domains. The network can learn to add a stain to images which is not present in the source domain, e.g we are able to create a full HE-stained image from an image which has only a single stain (onlyH, onlyE) or vice versa. This can simplify the manual staining process. How this affects other stains besides HE needs further investigation.

Conclusion

In this paper we show that CycleGANs are a powerful tool for normalization of different variants of HE-stains and tissue types. We validated this approach on data sets covering images from different scanning devices, staining protocols and tissue types and additionally showed the impact on stain normalization on the downstream task of image classification. The method has been successfully applied to compensate for variances resulting from image acquisition as well as from tissue staining while preserving structural content of the images. In order to make use of this approach in a clinical manner, the training process should be accelerated, i.e. using transfer learning, an increased batch size and specialized hardware. The method may be added to various image processing frameworks at WSI level to be applied to tasks such as classification or segmentation.

Appendix

Table 3.

FID scores for all experiments between real and generated (fake, rec) images for A and B

FID MA14 shortHE longHE onlyH onlyE
XAreal vs. XBreal 31.5017 59.4240 51.4460 119.0061 203.6761
XAreal vs. XAfake 12.1464 4.5465 6.0007 4.1793 8.5647
XAreal vs. XArec 4.0544 4.2877 7.8630 4.0363 8.5685
XBreal vs. XBfake 10.3222 4.0365 5.3136 7.0321 7.9218
XBreal vs. XBrec 2.6451 6.3173 2.9931 4.9206 11.0160

Table 4.

SSIM scores (SD = standard deviation) for all experiments between real and rec images for A and B

SSIM (SD) MA14 shortHE longHE onlyH onlyE
XAreal vs. XArec 0.9406 (0.0147) 0.9724 (0.0055) 0.9572 (0.0073) 0.9731 (0.0057) 0.9534 (0.0080)
XBreal vs. XBrec 0.9606 (0.0148) 0.9760 (0.0063) 0.9702 (0.0098) 0.9763 (0.0056) 0.9648 (0.0107)

Table 5.

Kappa-values for the ResNet models that were trained on different versions of the Camelyon16 data set

model / data Cam_ori Cam_HE Cam_onlyH Cam_TL TL_ori TL_onlyH TL_HE TL_Cam
ResNet_ori 0.85 0.00 0.00 0.12 0.00 0.00 0.00 0.54
ResNet_HE 0.02 0.79 0.01 0.28 0.13 0.00 0.55 0.01
ResNet_onlyH 0.00 0.00 0.77 0.14 0.03 0.53 0.00 0.00
ResNet_TL 0.36 0.10 0.53 0.79 0.55 0.38 0.08 0.24

The best kappa value obtained for each test set (column-wise) on all models is shown in bold

Acknowledgements

We thank our project partners Smart In Media AG for the collaboration in this project.

Abbreviations

HE

Hematoxylin-eosin

GAN

Generative adversarial network

FID

Fréchet inception distance

SSIM

Structural similarity index measure

Authors’ contributions

M. Runz: study design and coordination, data formation, model training, statistical evaluation, manuscript drafting. D. Rusche: statistical evaluation, manuscript drafting. S. Schmidt: manuscript drafting. M. R. Weihrauch: manuscript drafting. J. Hesser: study design and coordination, manuscript drafting. C.A. Weis: study design and coordination, data formation, model training, statistical evaluation, manuscript drafting. The author(s) read and approved the final manuscript.

Funding

Our work is supported by the grant ZIM ZF4689501TS9. Open Access funding enabled and organized by Projekt DEAL.

Availability of data and materials

The code is publicly available at https://github.com/m4ln/stainTransfer_CycleGAN_pytorch. The data set supporting the solutions is available at 10.11588/data/8LKEZF.

Declarations

Competing interests

The authors declare that they have no competing interests.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Marlen Runz, Email: marlen.runz@medma.uni-heidelberg.de.

Daniel Rusche, Email: d.rusche@stud.uni-heidelberg.de.

Stefan Schmidt, Email: s.schmidt@hs-mannheim.de.

Martin R. Weihrauch, Email: m.weihrauch@smartinmedia.com

Jürgen Hesser, Email: juergen.hesser@medma.uni-heidelberg.de.

Cleo-Aron Weis, Email: cleo-aron.weis@medma.uni-heidelberg.de.

References

  • 1.Bianconi F, Kather JN, Reyes-Aldasoro CC. Experimental assessment of color deconvolution and color normalization for automated classification of histology images stained with hematoxylin and eosin. Cancers. 2020; 12(11). 10.3390/cancers12113337. [DOI] [PMC free article] [PubMed]
  • 2.Bukenya F. A hybrid approach for stain normalisation in digital histopathological images. Multimed Tools Appl. 2020;79(3):2339–2362. doi: 10.1007/s11042-019-08262-0. [DOI] [Google Scholar]
  • 3.Vicory J, Couture HD, Thomas NE, Borland D, Marron JS, Woosley J, Niethammer M. Appearance normalization of histology slides. Comput Med Imaging Graph. 2015;43:89–98. doi: 10.1016/j.compmedimag.2015.03.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Khan AM, Rajpoot N, Treanor D, Magee D. A nonlinear mapping approach to stain normalization in digital histopathology images using image-specific color deconvolution. IEEE Trans Biomed Eng. 2014;61(6):1729–1738. doi: 10.1109/TBME.2014.2303294. [DOI] [PubMed] [Google Scholar]
  • 5.Macenko M, Niethammer M, Marron JS, Borland D, Woosley JT, Guan X, Schmitt C, Thomas NE. A method for normalizing histology slides for quantitative analysis. In: 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro: 2009. p. 1107–1110. 10.1109/ISBI.2009.5193250.
  • 6.Bautista PA, Yagi Y. Staining correction in digital pathology by utilizing a dye amount table. J Digit Imaging. 2015;28(3):283–294. doi: 10.1007/s10278-014-9766-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Ruifrok A, Johnston D. Quantification of histochemical staining by color deconvolution. Anal Quant Cytol Histol. 2001;23(4):291–9. [PubMed] [Google Scholar]
  • 8.Reinhard E, Adhikhmin M, Gooch B, Shirley P. Color transfer between images. IEEE Comput Graph Appl. 2001;21(5):34–41. doi: 10.1109/38.946629. [DOI] [Google Scholar]
  • 9.Ghazvinian Zanjani F, Zinger S, Ehteshami Bejnordi B, van der Laak J, With P. Stain normalization of histopathology images using generative adversarial networks: 2018. p. 573–577. 10.1109/ISBI.2018.8363641.
  • 10.Shaban MT, Baur C, Navab N, Albarqouni S. StainGAN: stain style transfer for digital histological images. 2018. http://arxiv.org/abs/1804.01601. Accessed 09 Dec 2020.
  • 11.Swiderska-Chadaj Z, de Bel T, Blanchet L, Baidoshvili A, Vossen D, van der Laak J, Litjens G. Impact of rescanning and normalization on convolutional neural network performance in multi-center, whole-slide classification of prostate cancer. Sci Rep. 2020;10(1):14398. doi: 10.1038/s41598-020-71420-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.de Bel T, Hermsen M, Kers J, van der Laak J, Litjens G. Stain-transforming cycle-consistent generative adversarial networks for improved segmentation of renal histopathology. In: Cardoso MJ, Feragen A, Glocker B, Konukoglu E, Oguz I, Unal G, Vercauteren T, editors. Proceedings of The 2nd International Conference on Medical Imaging with Deep Learning. Proceedings of Machine Learning Research, vol. 102. London: PMLR; 2019. [Google Scholar]
  • 13.Mahapatra D, Bozorgtabar B, Thiran J-P, Shao L. Structure Preserving Stain Normalization of Histopathology Images Using Self-Supervised Semantic Guidance. 2020. http://arxiv.org/abs/2008.02101. Accessed 09 Dec 2020.
  • 14.Zhu J-Y, Park T, Isola P, Efros AA. Unpaired Image-to-Image Translation using Cycle-Consistent Adversarial Networks. 2020. http://arxiv.org/abs/1703.10593. Accessed 09 Dec 2020.
  • 15.Goodfellow IJ, Pouget-Abadie J, Mirza M, Xu B, Warde-Farley D, Ozair S, Courville A, Bengio Y. Generative Adversarial Networks. 2014. http://arxiv.org/abs/1406.2661. Accessed 09 Dec 2020.
  • 16.Ehteshami Bejnordi B, Veta M, Johannes van Diest P, van Ginneken B, Karssemeijer N, Litjens G, van der Laak JAWM, the CAMELYON16 Consortium Diagnostic Assessment of Deep Learning Algorithms for Detection of Lymph Node Metastases in Women With Breast Cancer. JAMA. 2017;318(22):2199–2210. doi: 10.1001/jama.2017.14585. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.MITOS-ATYPIA-14 Grand Challenge. https://mitos-atypia-14.grand-challenge.org/. Accessed 22 Mar 2020.
  • 18.Runz M, Weis C-A. Normalization of HE-Stained Histological Images using Cycle Consistent Generative Adversarial Networks [Dataset]. heiDATA. 2021. 10.11588/data/8LKEZF. [DOI] [PMC free article] [PubMed]
  • 19.He K, Zhang X, Ren S, Sun J. Deep Residual Learning for Image Recognition. 2015. http://arxiv.org/abs/1512.03385. Accessed 11 May 2021.
  • 20.Brownlee J. How to implement the frechet inception distance (fid) for evaluating gans. 2019. https://machinelearningmastery.com/how-to-implement-the-frechet-inception-distance-fid-from-scratch/. Accessed 15 Jan 2021.
  • 21.Heusel M, Ramsauer H, Unterthiner T, Nessler B, Hochreiter S. GANs Trained by a Two Time-Scale Update Rule Converge to a Local Nash Equilibrium. 2018. http://arxiv.org/abs/1706.08500. Accessed 15 Jan 2021.
  • 22.w, 13b3. SSIM-py Structural Similarity (SSIM) index, where the core dependency is NumPy. 2019. https://github.com/w13b3/SSIM-py. Accessed 20 Dec 2020.
  • 23.Wang Z, Bovik AC, Sheikh HR, Simoncelli EP. Image quality assessment: from error visibility to structural similarity. IEEE Trans Image Process. 2004;13(4):600–612. doi: 10.1109/TIP.2003.819861. [DOI] [PubMed] [Google Scholar]
  • 24.Seitzer M. pytorch-fid: FID Score for PyTorch. 2020. https://github.com/mseitzer/pytorch-fid. Version 0.1.1.. Accessed 18 May 2021.
  • 25.Pedregosa F, Varoquaux G, Gramfort A, Michel V, Thirion B, Grisel O, Blondel M, Prettenhofer P, Weiss R, Dubourg V, Vanderplas J, Passos A, Cournapeau D, Brucher M, Perrot M, Duchesnay E. Scikit-learn: Machine learning in Python. J Mach Learn Res. 2011;12:2825–2830. [Google Scholar]
  • 26.McHugh ML. Interrater reliability: the kappa statistic. Biochemia Medica. 2012;22(3):276–282. doi: 10.11613/BM.2012.031. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Buslaev A, Iglovikov VI, Khvedchenya E, Parinov A, Druzhinin M, Kalinin AA. Albumentations: Fast and flexible image augmentations. Information. 2020; 11(2). 10.3390/info11020125.
  • 28.Yuan E, Suh J. Neural stain normalization and unsupervised classification of cell nuclei in histopathological breast cancer images. arXiv preprint arXiv:1811.03815. 2018.

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The code is publicly available at https://github.com/m4ln/stainTransfer_CycleGAN_pytorch. The data set supporting the solutions is available at 10.11588/data/8LKEZF.


Articles from Diagnostic Pathology are provided here courtesy of BMC

RESOURCES