Table 3.
Correlation coefficient r and associated p-value between WOB/VT and breathing resistance at different work rates for inhalation and exhalation by classes of respirators.
| Variable | Variable | Correlation coefficient r | p-value for all classes | |||
|---|---|---|---|---|---|---|
| Full-facepiece | Half-mask elastomeric | Filtering facepiece | All classes | |||
| WOBin/VT Resting | Inhalation resistance | 0.84 | 0.72 | 0.77 | 0.26 | 0.127 |
| WOBin/VT W1 | 0.81 | 0.80 | 0.83 | 0.71 | <0.0001 | |
| WOBin/VT W2 | 0.79 | 0.83 | 0.74 | 0.86 | <0.0001 | |
| WOBin/VT W3 | 0.72 | 0.82 | 0.46 | 0.89 | <0.0001 | |
| WOBin/VT W4 | 0.80 | 0.79 | 0.25 | 0.90 | <0.0001 | |
| WOBex/VT Resting | Exhalation resistance | 0.66 | 0.17 | 0.91 | 0.79 | <0.0001 |
| WOBex/VT W1 | 0.91 | 0.80 | 0.93 | 0.84 | <0.0001 | |
| WOBex/VT W2 | 0.90 | 0.67 | 0.92 | 0.88 | <0.0001 | |
| WOBex/VT W3 | 0.81 | 0.47 | 0.92 | 0.73 | <0.0001 | |
| WOBex/VT W4 | 0.74 | 0.54 | 0.92 | 0.59 | <0.0001 | |