Table 5.

Effective PBM treatment: in vivo on tissues with higher number of mitochondria.

Authors Wavelength (nm) Fluence Irradiance Tissue type
Alves et al.25 808 142.4  J/cm2 1.78  W/cm2
4 J, 50 mW, 0.028  cm2, 80 s per point
Arthritis
Oron et al.62,63 810 0.3  J/cm2 5  mW/cm2
5 mW, area 1.1  cm2, 60 s
Heart
Oron et al.62,63 810 0.9  J/cm2 5  mW/cm2 Myocardium tissue
Castano et al.17 810 30  J/cm2 50  mW/cm2 Arthritis
Castano et al.17 810 30  J/cm2 5  mW/cm2 Arthritis
Castano et al.17 810 3  J/cm2 5  mW/cm2 Arthritis
Salehpour et al.59 810 1.2  J/cm2 560  mW/cm2
39.3 W, spot size 0.07  cm2
Brain
Salehpour et al.64 810 8  J/cm2 89  mW/cm2
6.2 W, spot size 0.07  cm2
Brain
Wu et al.78 810 36  J/cm2 15  mW/cm2 Brain
Blanco et al.70 1064 250  mW/cm2 60  J/cm2 Brain (human)
Disner et al.71 1064 250  mW/cm2 60  J/cm2 Brain (human)
Ando et al.13 810 36  J/cm2 50  mW/cm2 TBI
Zhang et al.67 810 Fluence reaching the cortex 1.8 to 2.5  J/cm2
Average irradiance 36  J/cm2
150  mW/cm2
Pulse freq 10 Hz, pulse duration 50 ms, 4 min
TBI
Salehpour et al.68 810 1.2  J/cm2 89 and 562  mW/cm2
35 and 240 mW
10 Hz, 50% duty cycle; 0.07  cm2
Brain
Baroni et al.68 Cluster with 69 LEDs 660/850 nm 206.89  J/cm2 6.89  W/cm2
200 mW; 6 J per diode (30 s); 0.02  cm2
30 J per application point (5×6  J)6 application points: total energy 180 J
Femoral quadriceps
Zhang et al.80 635 0.96  J/cm2 6.37  mW/cm2
5 mW, laser beam width 10 mm, 150 s
Preconditioning myocardium
Salehpour et al.59 660 8  J/cm2 4.75  W/cm2
88% duty cycle, 200 mW, in contact three times a week, 7 mm diameter
Brain
Wu et al.78 660 36  J/cm2 15  mW/cm2 Brain
Lopes-Martins et al.18 655 0.5  J/cm2 31.25  mW/cm2
2.5 mW, spot area 0.08  cm2, 25 mW, 32 s
Muscle
Lopes-Martins et al.18 655 1  J/cm2 31.25  mW/cm2
2.5 mW, spot area 0.08  cm2, 25 mW, 80 s, 2.5 mW
Muscle