Skip to main content
. 2021 Aug 3;2021:8881794. doi: 10.1155/2021/8881794

Table 2.

Refractive outcomes and monocular visual acuity in patients who underwent mix-and-match implantation of an extended depth of focus and a +3.25 D near add diffractive multifocal intraocular lens.

LogMAR UDVA LogMAR UIVA LogMAR UNVA LogMAR CDVA
Preoperative Dominant eye 0.40 ± 0.25 (range: 0–0.80) 0.53 ± 0.26 (range: 0.20–1.00) 0.57 ± 0.23 (range: 0.20–1.00) 0.19 ± 0.20 (range: 0–0.50)
Nondominant eye 0.45 ± 0.31 (range: 0.10–0.90) 0.55 ± 0.23 (range: 0.20–1.00) 0.67 ± 0.23 (range: 0.30–1.00) 0.17 ± 0.14 (range: 0–0.50)

1-month postoperative Dominant eye 0.11 ± 0.09 (range: 0–0.30) 0.14 ± 0.11 (range: 0–0.30) 0.26 ± 0.18 (range: 0–0.50) 0.02 ± 0.06 (range: 0–0.10)
P value <.001 <.001 .011 <.001
Nondominant eye 0.12 ± 0.11 (range: 0–0.30) 0.18 ± 0.13 (range: 0–0.50) 0.21 ± 0.13 (range: 0–0.50) 0.04 ± 0.05 (range: 0–0.20)
P value <.001 <.001 <.001 <.001

3-month postoperative Dominant eye 0.07 ± 0.09 (range: 0–0.40) 0.11 ± 0.11 (range: 0–0.30) 0.25 ± 0.15 (range: 0–0.40) 0.02 ± 0.05 (range: 0–0.10)
P value <.001 <.001 .009 <.001
Nondominant eye 0.12 ± 0.11 (range: 0–0.30) 0.16 ± 0.12 (range: 0–0.40) 0.22 ± 0.16 (range: 0–0.40) 0.04 ± 0.07 (range: 0–0.20)
P value <.001 <.001 <.001 <.001

Results reported as means ± standard deviations. UDVA: uncorrected distance visual acuity; UIVA: uncorrected intermediate visual acuity; UNVA: uncorrected near visual acuity; CDVA: corrected distance visual acuity. Compared with preoperative values.