TABLE 5. Segmentation Time – Mask Contains Aorta and Coronary Arteries.

With aorta Time (average) Time (SD)
Simpleware-ScanIP 203.07s 101.69s
Our method (GPU) 3.29s 0.47s
Our method (CPU only – 2 cores, 4 threads) 138.57s 15.74s
Our method (CPU only – 16 cores, 32 threads) 40.93s 4.71s