Skip to main content
. 2021 May 7;16(13):2089–2093. doi: 10.1002/cmdc.202100067

Table 2.

Temperature‐dependent decomposition of compound 1 in DMSO.

graphic file with name CMDC-16-2089-g003.jpg

Activity measured after 3 months

RT[b]

+4 °C[b]

−20 °C[b]

1 ‐ Old sample[c]

PfIspE IC50m][a]

12±4

16±7

>500

10±3

PK/LDH IC50m][a]

34±4

45±6

n.d.

40±4

EcIspE IC50m][a]

101±14

71±10

>500

32±6

Degradation after 2 months

100%

79%

18%

N/A

[a] Errors given as formal standard error. [b] HRMS chromatograms measured shortly before the assay are given in SI, Figure S7. [c] The control values for the old decomposed sample run at the same time. n.d.: not determined, N/A: not applicable, PK/LDH: pyruvate kinase and lactate dehydrogenase, Pf: Plasmodium falciparum, Ec: Escherichia coli, RT: room temperature.