Skip to main content
. Author manuscript; available in PMC: 2022 Apr 1.
Published in final edited form as: Ann Biomed Eng. 2020 Oct 16;49(4):1151–1168. doi: 10.1007/s10439-020-02631-9

Table 3.

Median[IQR] values for hemodynamics calculated in the training and testing dataset based on invasive (IVUS/OCT) and noninvasive (CTA) imaging.

Training Data Testing Data
CTA Median [IQR] OCT/IVUS Median [IQR] p-value CTA Median [IQR] OCT/IVUS Median [IQR] p-value
TAESS¯seg (dyne/cm2) 50.1[25.8–90.1] 31.7 [19.3–62.4] <0.001 30.1[17.1–83.8] 15.8[8.8–63.4] <0.001
TAESS¯arc (dyne/cm2) 47.7[24.1–90.0] 29.9 [18.1–62.4] <0.001 29.4[16.2–74.7] 15.0[8.9–57.4] <0.001
TAESSmin (dyne/cm2) 16.2[6.7–34.7] 10.3[4.4–19.5] 0.006 13.4[6.1–25.9] 6.0[4.1–17.1] <0.001
TAESSmax (dyne/cm2) 90.3[42.8–167.6] 55.3[34.0–117.3] 0.007 51.8[27.4–128.4] 25.6[18.0–120.9] <0.001
OSI¯seg (x10−4) 6.3[2.0–34.0] 1.1[2.0–51.0] 0.15 8.5[3.0–24.0] 23.0[7.0–57.0] <0.001
P¯seg (mmHg) 84.8[52.5–100.5] 69.2[43.1–87.6] <0.001 96.3[70.9–98.9] 78.8[78.5–90.3] <0.001
Dia (mm) 2.2[1.8–2.7] 2.4[2.0–3.1] <0.001 2.5[1.9–3.0] 3.1[2.2–3.6] <0.001

TAESS¯seg: segment-averaged time averaged endothelial shear stress; TAESS¯arc: arc-averaged time averaged endothelial shear stress; TAESSmin,TAESSmin: minimum and maximum time averaged endothelial shear stress in each 2mm segment; OSI¯seg: segment-averaged oscillatory shear index; P¯seg: segment-averaged time averaged pressure; Dia: lumen diameter