Skip to main content
. 2021 Aug 13;31(1-2):234–246. doi: 10.1007/s11666-021-01242-7

Table 5.

Mass/volume loss increments of the WC-CoCr, WC-CrC-Ni coatings, and AISI 1040 steel during cavitation tests (average of three measurements)

Time, min AISI 1040 steel WC-CoCr coating WC-CrC-Ni coating
Mass loss, mg Volume loss, mm3 Mass loss, mg Volume loss, mm3 Deviation, mm3 Mass loss, mg Volume loss, mm3 Deviation, mm3
0 0.00 0.00 0.00 0.00 ± 0.00 0.00 0.00 ± 0.00
15 4.55 0.58 2.00 0.14 ± 0.08 3.75 0.29 ± 0.02
30 3.00 0.38 3.95 0.28 ± 0.14 2.05 0.16 ± 0.06
90 27.50 3.50 18.65 1.33 ± 0.27 9.60 0.73 ± 0.44
150 31.35 3.99 21.65 1.54 ± 0.35 13.60 1.13 ± 0.45
210 50.20 6.39 16.90 1.20 ± 0.26 16.45 1.25 ± 0.45
270 36.30 4.62 22.70 1.62 ± 0.49 20.35 1.45 ± 0.28
330 34.75 4.43 17.15 1.22 ± 0.64 15.90 1.21 ± 0.49