Detection of SARS-CoV-2 in saliva samples using RT-LAMP. RT-LAMP analysis of saliva samples of confirmed COVID-19 patients who (A) induced or not (B) salivation before sample collection. (C) Comparison of RT-LAMP and RT-PCR results. The Ct values (RT-PCR results) of 39 COVID-19 positive patients (y-axis) were compared to the RT-LAMP readout of the matched saliva samples (x-axis), after 30 min of incubation at 65 °C (positive, +/yellow; negative, −/pink). Black circles—direct saliva; orange circles—RNA extracted from saliva. (D) RNAs from the saliva of false negative samples (as determined by the direct saliva test) were extracted using plasmid DNA miniprep columns (ZR Plasmid Miniprep-Classic Kit, Zymo Research) and re-analyzed. NTC no template control. Cts (N gene) obtained for the paired NP samples are indicated.