Table 3.
I. Training Group | |||||
---|---|---|---|---|---|
Step | Patient #1 | Patient #2 | Patient #3 | Patient #4 | Patient #5 |
#1 | MV stenting Resolute integrity 3.5 × 18 mm@8 atm | MV pre-dilatation SC balloon 2.5 × 15 mm@14 atm |
MV stenting Resolute integrity 3.0 × 38 mm@12 atm |
MV pre-dilatation Compliant balloon 2 × 20 mm@8 atm | MV stenting Resolute Onyx 2.5 × 18 mm@18 atm |
#2 |
1st POT NC balloon 3.75 × 8 mm@18 atm |
MV stenting Resolute integrity 2.5 × 18 mm@12 atm |
1st POT NC balloon 3.5 × 6 mm@18 atm |
MV stenting Resolute Onyx 3 × 22 mm@14 atm |
1st POT NC balloon 3.5 × 8 mm@18 atm |
#3 |
2nd POT NC balloon 3.75 × 8 mm@18 atm |
KBI SC balloon 2.5 × 15 mm@14 atm in MV and SC balloon 2 × 15 mm@8 atm in SB |
2nd POT NC balloon 3.5 × 6 mm@18 atm, more proximally than step #2 |
1st POT Stent balloon 3 × 22 mm@14 atm more proximally than step #2 |
2nd POT NC balloon 3.5 × 8 mm@18 atm, more proximally than step #2 |
#4 |
SB strut opening SC balloon 2.5 × 4 mm@6 atm |
3rd POT NC balloon 3.5 × 6 mm@18 atm, more proximally than step #3 |
SB strut opening Compliant balloon 2.5 × 20 mm@6 atm |
SB strut opening NC balloon 2.25 × 12 mm@14 atm |
|
#5 |
SB strut opening Compliant balloon 1.5 × 15 mm@10 atm |
1st KBI NC balloon 2.75 × 15 mm@6 atm in MV and compliant balloon 2.5 × 20 mm@6 atm in SB |
3rd POT NC balloon 3.5 × 8 mm@18 atm, more proximally than step #3 |
||
#6 |
2nd KBI NC balloon 2.75 × 15 mm@6 atm in MV more proximally than step #5 and compliant balloon 2.5 × 20 mm@6 atm in SB |
II. Testing Group | |||||
---|---|---|---|---|---|
Step | Patient #6 | Patient #7 | Patient #8 | Patient #9 | Patient #10 |
#1 |
1st MV pre-dilatation NC balloon 3.0 × 12 mm@16 atm |
MV pre-dilatation SC balloon 2.5 × 15 mm@6 atm |
MV stenting Resolute Integrity 2.75 × 22 mm@10 atm |
Pre-dilatation SC balloon 3.0 × 15 mm@14 atm |
MV stenting Resolute Onyx 3.0 × 18 mm@12 atm |
#2 |
2nd MV pre-dilatation NC balloon 3.0 × 12 mm@16 atm more distally than step #1 |
MV stenting Resolute Integrity 2.5 × 18 mm@16 atm |
SB strut opening NC balloon 2.25 × 12 mm@8 atm |
MV stenting Resolute Onyx 3.5 × 18 mm@12 atm |
SB strut opening NC balloon 2.0 × 12 mm@14 atm |
#3 |
3rd MV pre-dilatation NC balloon 3.0 × 12 mm@16 atm more proximally than step #1 |
1st POT Stent balloon 2.5 × 18 mm@16 atm more proximally than step #2 |
POT NC balloon 2.5 × 12 mm@12 atm |
1st POT NC balloon 3.75 × 8 mm@14 atm |
Post-dilatation Stent balloon 3.0 × 18 mm@12 atm |
#4 |
MV stenting Resolute Integrity 3.0 × 38 mm@12 atm |
2nd POT NC balloon 3.0 × 8 mm@14 atm |
1st KBI NC balloon 2.5 × 12 mm@12 atm in MV and NC balloon 2.25 × 12 mm@8 atm in SB |
2nd POT NC balloon 3.75 × 8 mm@14 atm, more proximally than step #3 |
1st KBI SC balloon 3.0 × 18 mm@12 atm in MV and NC balloon 2.0 × 12 mm@14 atm in SB |
#5 |
SB strut opening SC balloon 2.0 × 15 mm@6 atm |
3rd POT NC balloon 3.0 × 8 mm@14 atm more proximally than step #4 |
2nd KBI NC balloon 2.5 × 12 mm@12 atm in MV and NC balloon 2.25 × 12 mm@8 atm in SB more proximally than step #4 |
SB strut opening NC balloon 2.25 × 8 mm@12 atm |
2nd KBI SC balloon 3.0 × 18 mm@12 atm in MV and NC balloon 2.0 × 12 mm@14 atm in SB more proximally than step #4 |
#6 |
KBI NC balloon 3.0 × 12 mm@6 atm in MV and SC balloon 2.0 × 15 mm@6 atm in SB |
4th POT NC balloon 3.0 × 8 mm@14 atm more proximally than step #5 |
|||
#7 |
POT NC balloon 3.0 × 12 mm@6 atm |
SB strut opening SC balloon 2.0 × 4 mm@6 atm |
MV main vessel, SB side branch, POT proximal optimization technique, KBI kissing balloon inflation, NC non-compliant, SC semi-compliant, atm atmosphere.