Skip to main content
. 2021 Aug 6;118(32):e2025562118. doi: 10.1073/pnas.2025562118

Table 1.

Electrode structure characterization and comparison to CAD model

SC FCC
Exp CAD Diff, % Exp CAD Diff, %
Area/volume, 1/m 2,989 3,424 14.5 4,473 4,805 7.42
Porosity 0.223 0.305 36.8 0.245 0.278 13.5

CAD, value measured from the idealized CAD model; Diff, relative difference between the two values; Exp, experimentally measured value from analysis of the tomographic images.