Table 4.
Electrical energy consumption of FD and different IRAFD trials for dried strawberry
| Methods | Vacuum pump (× 103 kJ) | Condenser (× 103 kJ) | IR lamp (× 103 kJ) | Total (× 103 kJ) |
|---|---|---|---|---|
| FD | 9.83 ± 0.40a | 13.66 ± 4.88a | - | 23.49 ± 5.17a |
| IRAFD-1.6 kW/m2 at 60% WR | 7.52 ± 0.09b | 13.32 ± 0.044ab | 0.35 ± 0.07b | 20.85 ± 0.08ab |
| IRAFD-1.6 kW/m2 at 40% WR | 6.27 ± 0.05c | 11.52 ± 0.23abc | 0.44 ± 0.06ab | 17.80 ± 0.20bc |
| IRAFD-1.6 kW/m2 at 20% WR | 5.16 ± 0.26d | 9.38 ± 0.40bc | 0.48 ± 0.03a | 14.55 ± 0.26c |
| Continuous IRAFD-1.6 kW/m2 | 4.64 ± 0.08e | 8.98 ± 0.10c | 0.54 ± 0.10a | 13.63 ± 0.09c |
a–eMeans (± SD) with a different letter in the same column are significantly different at p < 0.05
WR weight reduction