Skip to main content
. 2021 Jul 6;30(8):1051–1061. doi: 10.1007/s10068-021-00940-w

Table 3.

Oxidative stability by DSC and estimation of the oils shelf life

Tox
(°C)
tox
(min)
Ea
(J/mol)
Regression equation R2 Shelf-life at
30 °C (days)
CE 155 3.94 ± 0.09* 60,893.52 ln k = −0.043 T + 8.0442 0.9999 0.60
140 6.98 ± 0.41
125 14.72 ± 0.17
US-CE 160 2.32 ± 0.34 99,466.00 ln k =  −0.0653 T + 11.558 0.9953 10.24
150 5.73 ± 0.14
140 11.34 ± 0.19
Control 135 15.29 ± 0.00 114,772.94 ln k =  −0.085 T + 14.217 0.9956 81.01
130 22.88 ± 1.75
125 35.77 ± 0.00

CE (Cold extraction), US-CE (ultrasound-assisted cold extraction), Control (Hexane), DSC (Differential Scanning Calorimetry), Tox (oxidative induction temperature), tox (oxidative induction time), k (reaction rate constant), T (Reaction temperature), Ea (Activation energy), R2 (Correlation coefficient)

*Values expressed as average ± standard deviation