Table 5.

Changes in Degrees of Neck Range of Motion per CROM Measurement.

Directions of range of motion movement Baseline to end of intervention Baseline to 4-wk post intervention
Mean Standard error P value Mean Standard error P value
Forward flexion −7.27 2.36 .012 0.59 2.36 .807
Extension 8.30 3.51 .042 1.40 3.51 .699
Left lateral flexion 5.23 2.91 .103 6.00 2.91 .066
Right lateral flexion 4.82 2.64 .098 6.68 2.64 .030
Left lateral rotation 8.05 3.45 .045 0.45 3.45 .899
Right lateral rotation 10.64 2.50 .002 4.73 2.50 .089

Longitudinal mixed effects model-based estimates were used to analyze changes.